Multi-axial Active Isolation for Seismic Protection of Buildings
نویسندگان
چکیده
Structural control technology has been widely accepted as an effective means for the protection of structures against seismic hazards. Passive base isolation is one of the common structural control techniques used to enhance the performance of structures subjected to severe earthquake excitations. Isolation bearings employed at the base of a structure naturally increase its flexibility, but concurrently result in large base displacements. The combination of base isolation with active control, i.e., active base isolation, creates the possibility of achieving a balanced level of control performance, reducing both floor accelerations as well as base displacements. Many theoretical papers have been written by researchers regarding active base isolation, and a few experiments have been performed to verify these theories; however, challenges in appropriately scaling the structural system and modeling the complex nature of control-structure interaction have limited the applicability of these results. Moreover, most experiments only focus on the implementation of active base isolation under unidirectional excitations. Earthquakes are intrinsically multi-dimensional, resulting in out-of-plane responses, including torsional responses. Therefore, an active isolation system for buildings using multi-axial active control devices against multi-directional excitations must be considered. The focus of this research is the development and experimental verification of active isolation strategies for multi-story buildings subjected to bi-directional earthquake loadings. First, a model building is designed to match the characteristics of a representative full-scale structure. The selected isolation bearings feature low friction and high vertical stiffness, providing stable behavior. In the context of the multi-dimensional response control, three, custom-manufactured actuators are employed to mitigate both in-plane and out-of-plane responses. To obtain a high-fidelity model of the active isolation systems, a hybrid identification approach is used which combines the advantages of the lumped mass model and nonparametric methods. Control-structure interaction (CSI) is also included in the identified model to further enhance the control authority. By employing the H2/LQG control algorithm, the controllers for the hydraulic actuators promise high performance and good robustness. The active isolation is found to possess the ability to reduce base displacements, as well as producing comparable accelerations over the passive isolation. The proposed active isolation strategies are validated experimentally for a six-story building tested on the six degree-of-freedom shake table in the Smart Structures Technology Laboratory at the University of Illinois at Urbana-Champaign.
منابع مشابه
Multi-objective Optimization of Semi-active Control of Seismically Exited Buildings Using Variable Damper and Genetic Algorithms
Semi-active fluid viscous dampers as a subset of control systems have shown their ability to reduce seismic responses of tall buildings. In this paper, multi-objective optimization of the performance of this group of dampers in reducing the seismic responses of buildings is studied using multi-objective genetic algorithms. For numerical example, two 7 and 18 stories buildings are chosen and mod...
متن کاملThe study of seismic resistance of rubber-metal supports
This research reveals the efficiency of seismic isolation system in the form of rubber-metal supports with different height buildings at multi component seismic impact. As an example, seismically insulated monolithic reinforced concrete 5, 9 and 16 story buildings are considered. The solution of the problem is obtained by a direct integration of the motion equations for an explicit scheme in fi...
متن کاملRanking Passive Seismic Control Systems by Their Effectiveness in Reducing Responses of High-Rise Buildings with Concrete Shear Walls Using Multiple-Criteria Decision Making
In recent decades, the dual systems of steel moment-resisting frames and RC shear walls have found extensive application as lateral load-resisting systems for high-rise structures in seismically active areas. This paper investigated the effectiveness of tuned mass damper (TMD), viscous damper, friction damper, and the lead-core rubber bearing in controlling the damage and seismic response of hi...
متن کاملInfluence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملSimplified design guidelines for seismic base isolation in multi-storey buildings for Bangladesh National Building Code (BNBC)
Seismic base isolation is now a days moving towards a very efficient tool in seismic design of structure. Increasing flexibility of structure is well achieved by the insertion of these additional elements between upper structure and foundation as they absorb larger part of seismic energy. However in Bangladesh, this research is still young for building structures. Therefore, this is a burning q...
متن کامل