Passive and hybrid mitigation of potential near-fault inner pounding of a self-braking seismic isolator
نویسندگان
چکیده
A seismic isolated structure is usually a long-period structural system, which may encounter a lowfrequency resonance problem when subjected to a near-fault earthquake that usually has a long-period pulse-like waveform. This long-period wave component may result in an enlargement of the base displacement and a decrease of the isolation efficiency. To overcome this problem, a rolling-based seismic isolator, referred to as roll-n-cage (RNC) isolator, has been recently proposed. The RNC isolator has a built-in buffer (braking) mechanism that limits the peak isolator displacements under severe earthquakes and prevents adjacent structural pounding. This paper addresses the problem of passive and hybrid mitigation of the potential inner pounding of the self-braking RNC isolator under near-fault earthquakes. Numerical results show that the RNC isolator can intrinsically limit the isolator displacements under near-fault earthquakes with less severe inner pounding using additional hysteretic damping and active control forces. & 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Study and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems
In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...
متن کاملInfluence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملInfluence of the Isolator Characteristics on the Response of the Isolated Buildings in the Near-FaultEarthquakes
Seismic base isolation are devices that used to limit the human and material damage caused by an earthquake. This devices diffuse the energy induced at the time of the earthquake before being transferred to the structure.The base isolated structures when subjected to the near-fault eathquakes which contain long-period velocity pulses that may coincide with the period of base isolated structures...
متن کاملInvestigation of seismic damage index due to water level changes in reservoir through nonlinear dynamic analysis under Far-Fault and Near-Fault ground motions
In this study, reservoir water level effects on nonlinear dynamic response of concrete gravity dams are investigated. For this purpose, the nonlinear behavior of the dam concrete is captured using the concrete damage plasticity (CDP) on the non associated flow rule assumption. Water in the reservoir is represented by the Lagrangian (displacement-based) fluid finite elements. The program ABAQUS ...
متن کاملResponse of Seismically Isolated Steel Frame Buildings with Sustainable Lead-Rubber Bearing (LRB) Isolator Devices Subjected to Near-Fault (NF) Ground Motions
Base isolation has been used as one of the most wildly accepted seismic protection systems that should substantially dissociate a superstructure from its substructure resting on a shaking ground, thereby sustainably preserving entire structures against earthquake forces as well as inside non-structural integrities. Base isolation devices can operate very effectively against near-fault (NF) grou...
متن کامل