The use of selected neutron absorption resonance filters to suppress spurious events on hot neutron spectrometers
نویسندگان
چکیده
Resonant absorption can be used as a filter for high energy neutron spectroscopy. Here we report the transmission of eight thin foil filters: erbium, indium, iridium, dysprosium, hafnium, gadolinium, cadmium and samarium, measured using neutron time-of-flight techniques over a range of energies (1 meV to 10 eV). Measured transmission is converted into energy-dependent absorption cross-section which compares closely to tabulated values. Each resonance is characterized from 91 meV (samarium) to 2815 meV (gadolinium) by Lorentzian fits. Possibilities for the use of neutron filters depending on the type of spurious background are discussed and the performance is simulated for a specific example of a hot neutron triple axis spectrometer experiment. & 2015 Elsevier B.V. All rights reserved.
منابع مشابه
Passive neutron area monitor with CR39
Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...
متن کاملExperimental comparison of thermal neutron absorption cross section in nano and micro particles
The neutron collision cross-section is important in neutron use for a specific job, such as neutron therapy or even in nuclear reactors. In calculating computational codes such as MCNP, only information from the neutron-to-mass collision information contained in the computational code library is used, in the case of nanoscale particles in contrast to the mass of materials and / or particulate m...
متن کاملOptimization study for BNCT facility based on a DT neutron generator
Background: A Boron Neutron Capture Therapy (BNCT) facility, based on a DT neutron generator, with the final goal to find out a potential, alternative, solution to existing BNCT treatment facilities which are based on nuclear reactors is examined. Materials and Methods: With the aim of the MCNP4B Monte Carlo code different beam-shaping assembly (BSA) configurations were considered. Lead was sel...
متن کاملThe safety of a landmine detection system using graphite and polyethylene moderator
Background: Several landmine detection methods, based on nuclear techniques, have been suggested up to now. Neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. In this paper an optimized (safe and effective) moderating structure using an 241Am-Be neutron source for detecting landmines has been invest...
متن کاملInvestigation of Developed Shield Composition to Neutron Shielding in Treatment Room for BNCT to Reduce Clinical Effects
Background and Aim: One of the best radiotherapy methods that have been suggested for the treatment of cancers such as brain, head and neck, skin, and recently liver is boron neutron capture therapy. Therefore, neutron shielding in the treatment room is important because the absorption of neutrons in the shield may lead to the production of gamma rays, which can have destructive effects. While ...
متن کامل