Cavity-enhanced on-chip absorption spectroscopy using microring resonators.

نویسندگان

  • Arthur Nitkowski
  • Long Chen
  • Michal Lipson
چکیده

We demonstrate on-chip laser absorption spectroscopy using silicon microring resonators integrated with PDMS microfluidic channels. A 100 microm radius microring resonator with Q > 100,000 is used to enhance the interaction length between evanescent light and a cladding liquid. We measure absorption spectra of less than 2 nL of N-methylaniline from 1460 nm to 1610 nm with 1 nm resolution and effective free space path lengths up to 5 mm. This work can help realize a completely on-chip spectroscopy device for lab-on-a-chip applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-chip spectrophotometry for bioanalysis using microring resonators

We measure optical absorption in color-producing enzymatic reactions for biochemical analysis with a microscale optofluidic device. Cavity-enhanced laser spectrophotometry is performed on analytes within a microfluidic channel at visible wavelengths with silicon nitride microring resonators of 100 µm radius and quality factor of ~180,000. The resonator transmission spectrum is analyzed to deter...

متن کامل

Cavity-Enhanced IR Absorption in Planar Chalcogenide Glass Microdisk Resonators: Experiment and Analysis Citation

Planar microdisk optical resonators fabricated from Ge Sb S chalcogenide glass on a silicon substrate are applied for cavity-enhanced spectroscopic measurement of chemical molecular absorption fingerprint. A 0.02 cm detection limit for these devices is demonstrated. This detection limit represents a threefold improvement as compared to a straight waveguide sensor, while the physical device leng...

متن کامل

On-chip cavity-enhanced absorption spectroscopy using a white light-emitting diode and polymer mirrors.

We have developed a disposable microfluidic chip with integrated cavity mirrors comprised of two pieces of 3M Vikuiti™ enhanced specular reflector II (ESRII) film, for performing cavity-enhanced absorption spectroscopy with a white light-emitting diode (LED). Compared to measurements made with a chip without cavity mirrors, the absorption path length is enhanced by a maximum factor of 28 at 544...

متن کامل

Improving the detection limit for on-chip photonic sensors based on subwavelength grating racetrack resonators.

Compared to the conventional strip waveguide microring resonators, subwavelength grating (SWG) waveguide microring resonators have better sensitivity and lower detection limit due to the enhanced photon-analyte interaction. As sensors, especially biosensors, are usually used in absorptive ambient environment, it is very challenging to further improve the detection limit of the SWG ring resonato...

متن کامل

Direct measurement of the on-chip insertion loss of high finesse microring resonators in Si3N4-SiO2 technology

Microring resonators show the possibility for designing Very Large Scale Integrated (VLSI) photonic circuits by cascading them. In order to realize the devices, the on-chip insertion loss becomes an important parameter. The direct measurement of the on-chip insertion loss of a high finesse microring resonator will be presented. Its value (0.1 ± 0.1) dB is low, in agreement with calculations.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 16 16  شماره 

صفحات  -

تاریخ انتشار 2008