Stability of commonly used antibiotic solutions in an elastomeric infusion device.
نویسندگان
چکیده
BACKGROUND The Accufuser silicone-based elastomeric infusion device has recently been approved for the Canadian market. OBJECTIVE To evaluate the stability of 5 antibiotics (cefazolin, ceftazidime, ceftriaxone, clindamycin, and vancomycin) in either 5% dextrose in water (D5W) or 0.9% sodium chloride in water (NS) after storage in Accufuser disposable silicone balloon infusers. METHODS The study drugs were reconstituted, according to the manufacturers' directions, in polyvinyl chloride minibags with either D5W or NS, at 2 different concentrations. The resulting solutions were transferred to disposable silicone balloon infusers for storage at 4°C or at room temperature (23°C). The concentration of each drug in each solution was determined by validated stability-indicating liquid chromatographic methods after storage for 14 to 31 days. RESULTS Solutions of ceftriaxone in either diluent retained more than 95.2% of the initial concentration for 2 days at room temperature and more than 91.6% of the initial concentration for 14 days at 4°C. Solutions of cefazolin in D5W or NS retained more than 90% of the initial concentration for at least 3 days at room temperature and for at least 26 days at 4°C. Solutions of ceftazidime in D5W or NS retained more than 90% of the initial concentration for only 1 day when stored at room temperature and for at least 4 days at 4°C. Solutions of clindamycin or vancomycin in D5W or NS retained 90% of the initial concentration for at least 7.5 days at room temperature and at least 90% of the initial concentration for at least 27.8 days at 4°C. CONCLUSIONS Previously reported expiration dates for solutions stored in elastomeric infusion devices were not based on 95% confidence intervals and were often longer than expiration dates determined from the studies reported here, which are based on 95% confidence intervals. Comparison of the observed concentrations remaining between previously published studies and the studies reported here indicates that the Accufuser elastomeric infusion device did not adversely affect the stability of these drugs.
منابع مشابه
Chemical Stability of Ceftolozane/Tazobactam in Polyvinylchloride Bags and Elastomeric Pumps
BACKGROUND Elastomeric pumps are often used to administer intravenous antibiotics in the outpatient setting, but effective infusion requires that the drug remain stable in solution throughout the procedure. OBJECTIVE To determine the chemical stability of ceftolozane/tazobactam when reconstituted and stored over an extended time in the AccuFlo (EMED Technologies, El Dorado Hills, California) ...
متن کاملProtocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study
INTRODUCTION Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Seconda...
متن کاملStability Test of Ampicillin Sodium Solutions in the Accufuser® Elastomeric Infusion Device Using HPLC: UV Method
The stabilities of two kinds of solutions (30 mg/mL) of Ampicillin sodium in 0.9% NaCl in water (NS, normal saline) and in sterile water (SW) in the intravenous elastomeric infusion device (Accufuser) were evaluated based on recommended solutions and storage periods. The injectable NSand SW-Ampicillin solutions in the Accufuser device were stored and evaluated at controlled temperature (room te...
متن کاملChemical Stability of Telavancin in Elastomeric Pumps☆
BACKGROUND VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin...
متن کاملStability of Commonly Used Antibiotics Solutions in the Accufuser
Objectives: The stability of two kinds of solution of penicillin G potassium [PEN-K, 10K U/mL in 5% dextrose water, D5W and 50K U/mL in 0.9% sodium chloride in water, NS) into the intravenous infusion device, Accufuser ® , storage were evaluated at controlled temperature (CT, 4±2°C and RT, 25±2°C) during 6 weeks. Methods: Studies were performed using both NS (PEN-K 50K U/mL) and D5W (PEN-K 10K ...