Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of lung cancer patients – Results of a pilot study
نویسندگان
چکیده
Background: Analysis of exhaled breath, especially of volatile organic compounds (VOCs), is of increasing interest in the diagnosis of lung cancer. Compared to other methods of breath analysis, ion mobility spectrometry (IMS) offers a ten-fold higher detection rate of VOCs. By coupling the ion mobility spectrometer with a multi-capillary column as a pre-separation unit, IMS offers the advantage of an immediate two-fold separation of VOCs with visualisation in a threedimensional chromatogram. The total analysis time is about 500 s compared to gas chromatography/mass spectrometry (GC/MS) of about 1 h. Therefore it seemed reasonable to test IMS in breath analysis. Methods: In this pilot study 32 patients with lung cancer were subjected to a breath analysis by IMS. Their IMS-chromatograms were compared with those of 54 healthy controls. An IMS that was built for special clinical application was used to identify characteristic peaks of VOCs , which might be relevant for the diagnosis of lung cancer in exhaled air of 10 mL volume. Results: By a combination of 23 peak regions within the IMS-Chromatogram, patients with lung cancer, including a patient with carcinoma in situ, were classified and differentiated from healthy persons with an error rate of 0. Conclusion: Breath analysis by IMS can detect a discriminating combination of VOCs in lung cancer patients. By pattern recognition without the need for chemical analysis of the underlying VOCs, IMS has the potential to facilitate lung cancer diagnosis.
منابع مشابه
Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study.
BACKGROUND Analysis of exhaled breath, especially of volatile organic compounds (VOCs), is of increasing interest in the diagnosis of lung cancer. Compared with other methods of breath analysis, ion mobility spectrometry (IMS) offers a tenfold higher detection rate of VOCs. By coupling the ion mobility spectrometer with a multicapillary column as a pre-separation unit, IMS offers the advantage ...
متن کاملDETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملNoninvasive detection of lung cancer using exhaled breath
Early detection of lung cancer is a key factor for increasing the survival rates of lung cancer patients. The analysis of exhaled breath is promising as a noninvasive diagnostic tool for diagnosis of lung cancer. We demonstrate the quantitative analysis of carbonyl volatile organic compounds (VOCs) and identification of lung cancer VOC markers in exhaled breath using unique silicon microreactor...
متن کاملتجزیه آلکانها و آلدئیدهای درونزاد در هوای بازدم شاغلین در مواجهه با غبار حاوی سیلیس
Background & Objectives : Silica is one of the most air pollutant in workplaces which long-term occupational exposure to silica is associated with an increased risk for respiratory diseases such as silicosis. Silicosis is an oxidative stress related disease and can lead to the development of lung cancer. This study aims to analysis of endogenous alkanes and aldehydes in the exhaled breath...
متن کاملDiagnosis by Volatile Organic Compounds in Exhaled Breath from Lung Cancer Patients Using Support Vector Machine Algorithm
Monitoring exhaled breath is a very attractive, noninvasive screening technique for early diagnosis of diseases, especially lung cancer. However, the technique provides insufficient accuracy because the exhaled air has many crucial volatile organic compounds (VOCs) at very low concentrations (ppb level). We analyzed the breath exhaled by lung cancer patients and healthy subjects (controls) usin...
متن کامل