Optimization of a simple, automatable extraction method to recover sufficient DNA from low copy number DNA samples for generation of short tandem repeat profiles.

نویسندگان

  • Linnea A Schiffner
  • Ewelina J Bajda
  • Mechthild Prinz
  • James Sebestyen
  • Robert Shaler
  • Theresa A Caragine
چکیده

AIM To develop an automated, high throughput extraction protocol in order to produce database eligible profiles from fingerprints and other low copy number (LCN) DNA sources. METHODS Extraction of either purified control DNA or buccal cells, for example, with commercial kits was compared to extraction with a simple digestion buffer and a subsequent concentration and purification. Results were evaluated based on the amount of DNA recovered and the completeness of the DNA profiles produced. RESULTS Simple procedures with fewer steps were superior to commercial kits, such as DNA IQ (Promega, Madison, WI, USA) and QiaAmp (Qiagen, Valencia, CA, USA), and other protocols with many manipulations. The optimized protocol included a thirty-minute incubation with 0.01% SDS and proteinase K at 56 degrees C, followed by an incubation at 100 degrees C for 10 minutes. Concentration of the extract and removal of the SDS was accomplished with a Microcon 100 (Millipore, Bedford, MA, USA), which can be assembled into a 96 well plate, the Microcon-96 Retentate Assembly Plate (Millipore) for automation. The addition of 1 ng Poly A RNA to the Microcon significantly improved DNA recovery. CONCLUSION A one-step sample digestion followed by sample concentration/purification minimized sample loss and maximized amplification input. Moreover, this methodology can be easily adapted for automation. Implementation of this protocol, due to the numerous potential sources of LCN DNA samples, will enhance the recovery of biological evidence from crime scenes and may be a source of database profiles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct comparison of post-28-cycle PCR purification and modified capillary electrophoresis methods with the 34-cycle "low copy number" (LCN) method for analysis of trace forensic DNA samples.

The investigation of samples with low amounts of template DNA remains at the forefront of forensic DNA research and technology as it becomes increasingly important to gain DNA profile information from exceedingly trace levels of DNA. Previous studies have demonstrated that it is possible to obtain short tandem repeat (STR) profiles from <100pg of template DNA by increasing the number of amplifi...

متن کامل

Evaluation of a modified salt-out method for DNA extraction from whole blood lymphocytes: A simple and economical method for gene polymorphism

Extraction of high-quality and-quantity DNA is a fundamental requirement for genetic research. It is very important to address the use of DNA extraction methods that are simple and cost-effective in gene polymorphism with large number of samples. This study was designed to investigate the optimal DNA extraction from lymphocytic cells by salt-out method. In this study, 200 blood samples of the t...

متن کامل

Developmental validation of the PrepFiler Forensic DNA Extraction Kit for extraction of genomic DNA from biological samples.

The PrepFiler Forensic DNA Extraction Kit enables isolation of genomic DNA from a variety of biological samples. The kit facilitates reversible binding of DNA with magnetic particles resulting in high DNA recovery from samples with very low and high quantities of biological materials: 0.1 and 40 microL of human blood (donor 2) provided 14 and 2883 ng of DNA, respectively. Following the revised ...

متن کامل

An efficient and simple CTAB based method for total genomic DNA isolation from low amounts of aquatic plants leaves with a high level of secondary metabolites

An efficient DNA isolation protocol specifically modified to get pure quality DNA required for molecular studieshas been reported in this paper. Some aquatic plants (Potamogeton spp., Ceratophyllum demersum and Myriophyllum spicatum) were used for the study. The protocol developed will be useful in getting high and pure DNA. Instead of using the available DNA extraction kits, this protocol can ...

متن کامل

Highly effective DNA extraction method for nuclear short tandem repeat testing of skeletal remains from mass graves.

AIM To quantitatively compare a silica extraction method with a commonly used phenol/chloroform extraction method for DNA analysis of specimens exhumed from mass graves. METHODS DNA was extracted from twenty randomly chosen femur samples, using the International Commission on Missing Persons (ICMP) silica method, based on Qiagen Blood Maxi Kit, and compared with the DNA extracted by the stand...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Croatian medical journal

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2005