Feasibility and accuracy of nasal alar pulse oximetry.

نویسندگان

  • T E Morey
  • M J Rice
  • T Vasilopoulos
  • D M Dennis
  • R J Melker
چکیده

BACKGROUND The nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala. METHODS After IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve oxyhaemoglobin saturations of 70-100% measured by traditional co-oximetry from radial artery samples. Concurrent alar and finger pulse oximetry values were measured using probes designed for these sites. Data were analysed using the Bland-Altman method for multiple observations per subject. RESULTS Bias, precision, and accuracy root mean square error (ARMS) over a range of 70-100% were significantly better for the alar probe compared with a standard finger probe. The mean bias for the alar and finger probes was 0.73% and 1.90% (P<0.001), respectively, with corresponding precision values of 1.65 and 1.83 (P=0.015) and ARMS values of 1.78% and 2.72% (P=0.047). The coefficients of determination were 0.96 and 0.96 for the alar and finger probes, respectively. The within/between-subject variation for the alar and finger probes were 1.14/1.57% and 1.87/1.47%, respectively. The limits of agreement were 3.96/-2.50% and 5.48/-1.68% for the alar and finger probes, respectively. CONCLUSIONS Nasal alar pulse oximetry is feasible and demonstrates accurate pulse oximetry values over a range of 70-100%. The alar probe demonstrated greater accuracy compared with a conventional finger pulse oximeter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Congruency of Nasal Alar Pulse Oximetry and Arterial Blood Analysis in Patients with Burns Hospitalized in ICU

Introduction: Several pathological conditions can reduce blood supply to the organs, among which burns can be mentioned. By developing the volume depletion and reducing the cardiac contractility, burns can cause hypoperfusion. Further, in ICUs, since the finger pulse oximetryis commonly used instead of the measurement of the nasal alar oxygen saturation, the use of finger probe restricts pulse ...

متن کامل

Comparison of nasal and forehead oximetry accuracy and pressure injury in critically ill patients.

BACKGROUND In critically ill patients, clinicians can have difficulty obtaining accurate oximetry measurements. OBJECTIVE To compare the accuracy of nasal alar and forehead sensor measurements and incidence of pressure injury. METHODS 43 patients had forehead and nasal alar sensors applied. Arterial samples were obtained at 0, 24, and 120 hours. Oxygen saturations measured by co-oximetry we...

متن کامل

Assessment of clinical application of pulse oximetry probes in llamas and alpacas

The placement and accuracy of pulse oximeter probes can vary markedly among species. For our study, we aimed to assess the accuracy of pulse oximetry and to determine the most clinically useful sites for probe placement in llamas and alpacas. The objectives included an analysis of pulse oximetry probes for accurate assessment of llamas and alpacas and to determine the best placement of the prob...

متن کامل

Relationship between Hyperactivity of Depressor Septi Nasi Muscle and Changes of Alar Base and Flaring during Smile

BACKGROUND Hyperactivity of depressor septi nasi muscle leads to smiling deformity and nasal tip depression. Lateral fascicles of this muscle help in widening the nostrils. The purpose of this study was to evaluate the relationship between the nasal length changes and the alar base and the alar flaring changes during smile. METHODS Standard photographs are performed in the face and lat...

متن کامل

Nasal Alar Necrosis Following Hyaluronic Acid Injection into Nasolabial Folds: A Case Report

Injection of synthetic fillers for soft tissue augmentation is increasing over the last decade. One of the most common materials used is hyaluronic acid (HA) that is safe and temporary filler for soft tissue augmentation. We present a case of 54-year-old female who experienced vascular occlusion and nasal alar necrosis following HA injection to the nasolabial folds. She suffered from pain, necr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 112 6  شماره 

صفحات  -

تاریخ انتشار 2014