Optimal single 3T MR imaging sequence for HDR brachytherapy of cervical cancer
نویسندگان
چکیده
PURPOSE The superior image quality of 3 tesla (3T) magnetic resonance (MR) imaging in cervical cancer offers the potential to use a single image set for brachytherapy. This study aimed to determine a suitable single sequence for contouring tumour and organs at risk, applicator reconstruction, and treatment planning. MATERIAL AND METHODS A 3T (Skyra, Siemens Healthcare AG, Germany) MR imaging system with an 18 channel body matrix coil generated HDR cervical cancer brachytherapy planning images on 20 cases using plastic-based treatment applicators. Seven different T2-weighted Turbo Spin Echo (TSE) sequences including both 3D and contiguous 2D scans based on sagittal, axial (transverse), and oblique planes were analysed. Each image set was assessed for total scanning time and usefulness in tumour localization via inter- and intra-observer analysis of high-risk clinical target volume (HR CTV) contouring. Applicator reconstruction in the treatment planning system was also considered. RESULTS The intra-observer difference in HR CTV volumes between 2D and 3D axial-based image sets was low with an average difference of 3.1% for each observer. 2D and 3D sagittal image sets had the highest intra- and inter observer differences (over 15%). A 2D axial 'double oblique' sequence was found to produce the best intra- (average difference of 0.6%) and inter-observer (mean SD of 9.2%) consistency and greatest conformity (average 0.80). CONCLUSIONS There was little difference between 2D and 3D-based scanning sequences; however the increased scanning time of 3D sequences have potential to introduce greater patient motion artifacts. A contiguous 2D sequence based on an axial T2-weighted turbo-spin-echo (TSE) sequence orientated in all planes of the treatment applicator provided consistent tumour delineation whilst allowing applicator reconstruction and treatment planning.
منابع مشابه
Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملComparison the treatment time of cobalt and iridium sources in HDR brachytherapy
Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...
متن کاملEvaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
متن کاملCaudal epidural anesthesia during intracavitary brachytherapy for cervical cancer
It has been suggested that pain control during intracavitary brachytherapy for cervical cancer is insufficient in most hospitals in Japan. Our hospital began using caudal epidural anesthesia during high-dose-rate (HDR) intracavitary brachytherapy in 2011. The purpose of the present study was to retrospectively investigate the effects of caudal epidural anesthesia during HDR intracavitary brachy...