Measurement of instantaneous blood flow velocity and pressure in conscious man with a catheter-tip velocity probe.

نویسندگان

  • I T Gabe
  • J H Gault
  • J Ross
  • D T Mason
  • C J Mills
  • J P Schillingford
  • E Braunwald
چکیده

SUMMARY Twenty-three patients were investigated during diagnostic right and left cardiac catheterization with an electromagnetic catheter-tip velocity probe. The catheter contained a pressure lumen for simultaneous measurements of intravascular pressure. Average peak and mean blood velocities were 66 and 11 cm/sec in the ascending aorta, 57 and 10 cm/sec in the pulmonary artery, 28 and 12 cm/sec in the superior vena cava, and 26 and 13 cm/sec in the inferior vena cava. The velocity pattern in the ascending aorta was similar to that obtained by other methods. Positioning of the catheter in the ascending aorta required care; in one patient with aortic stenosis the recorded blood velocity pattern was unsatisfactory. In the pulmonary artery flicking of the catheter often produced artifacts in the records. The effect of deep respiration on blood velocity in the ascending aorta and pulmonary artery was studied. In the ascending aorta the highest velocities and stroke volumes were achieved during late expiration while in the pulmonary artery blood velocity and stroke volume were greatest in inspiration. In nine patients the cardiac outputs calculated from the product of mean velocity and radiologically measured cross-sectional area of the ascending aorta or pulmonary artery were compared with cardiac outputs determined by the indicator-dilution method; the correlation coefficient was 0.73. There were no complications, and the probe proved reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional evaluation of mitral valve prosthesis by Doppler blood velocimetry.

arious techniques have been utilized for the asVsessment of mitral valve prosthesis function in man. Of the external methods, phonocardiography, fluoroscopy, and echocardiography have been most frequently employed. Routine cardiac catheterization, including pressure measurement and left ventriculography, supplies important data but does not directly estimate blood flow through the d c i a l val...

متن کامل

Use of catheter-tip velocity--pressure transducer to evaluate left ventricular function in man: effects of intravenous propranolol.

A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat c...

متن کامل

Use of Catheter-tip. Velocity-Pressure Transducer

A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat c...

متن کامل

Mean Velocity and Static Pressure in a Sharp-edge Circular Nozzle Jet

An axisymmetric jet issued from a sharp edged circular convergent nozzle has been studied experimentally in the near field at Reynolds number 5.3x104  to search the saddle shape behavior of mean velocity and the role of mean static pressure in the jet flow. Due to the vena contracta effect the centerline mean velocity of the jet increases about 4.2% of its exit value and corresponding decrease ...

متن کامل

Pressure-radius relationship in large blood vessels of man.

• The measurement of instantaneous blood flow in the great vessels in man is of importance in the study of circulatory dynamics. With the pressure-gradient technique, it is possible to estimate instantaneous blood velocity in man. However, in order to compute instantaneous blood flow from blood velocity, the radius of the vessel under study must be known at every instant in the cardiac cycle. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 1969