Rapid determination of citrinin in corn by fluorescence liquid chromatography and enzyme immunoassay.
نویسندگان
چکیده
A rapid assay procedure was developed for mycotoxin citrinin in corn using liquid-liquid extraction (LLE) cartridges. Ground corn was extracted with methylene chloride and 0.5 N phosphoric acid. The extract was added to an LLE cartridge containing a diatomaceous-earth adsorbant, previously impregnated with sodium bicarbonate solution. After aspiration to dryness, the cartridge was eluted with methanol-water (4 + 1), and aliquots were taken for quantitation by reversed-phase liquid chromatography with fluorescence detection. Recoveries of citrinin added to ground corn at 200-1600 ng/g ranged from 71.2 to 86.3%, with coefficients of variation between 4.1 and 10.6%. An indirect enzyme immunoassay was also evaluated, using sodium carbonate solution for extraction. Recoveries of citrinin added to ground corn at 200-2000 ng/g ranged from 53.2 to 67.2%, but the coefficients of variation varied between 18.4 and 51.5%. The LLE cartridge procedure offers the advantages of low solvent consumption and speed, and is amenable to automation.
منابع مشابه
Determination of Citrinin Using Molecularly Imprinted Solid Phase Extraction Purification, HPLC Separation, and Fluorescence Detection
Determination of Citrinin Using Molecularly Imprinted Solid Phase Extraction Purification, HPLC Separation, and Fluorescence Detection Michael Appell, Michael A. Jackson, Lijuan C. Wang & Wayne B. Bosma To cite this article: Michael Appell, Michael A. Jackson, Lijuan C. Wang & Wayne B. Bosma (2015) Determination of Citrinin Using Molecularly Imprinted Solid Phase Extraction Purification, HPLC S...
متن کاملDetermination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method
BACKGROUND Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA...
متن کاملRapid method for determination of kanamycin and dibekacin in serum by use of high-pressure liquid chromatography.
A rapid, simple, and accurate method for the determination of kanamycin and dibekacin in serum by use of high-pressure liquid chromatography is described. The serum proteins were precipitated with 3.5% perchloric acid containing sodium octanesulfonate. After centrifugation, a sample of the supernatant was directly injected into the chromatograph. The determination of kanamycin and dibekacin was...
متن کاملCombined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy
This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...
متن کاملCombined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy
This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 82 6 شماره
صفحات -
تاریخ انتشار 1999