AbstractID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector
ثبت نشده
چکیده
ID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector Purpose: Lag in a-Si flat-panel detectors (FPD) causes significant artifact. To date, most correction models have assumed a linear, time-invariant model (LTIM). We investigated detector response as a function of incident exposure. Method and Materials: The physics theory for charge trapping in FPD detectors suggests that the process is non-linear and time variant. We measured the rising step response function (RSRF) and falling step response function (FSRF) as a function of incident exposure on a Varian 4030CB detector. An LTIM was implemented for lag reduction with temporal behavior of the panel modeled as a multi-exponential impulse response with four exponentials. The impact of using RSRF, FSRF and different incident exposures (0.5% 80% of saturation) on calibration coefficients of the LTIM was investigated in projection data and reconstructions of challenging phantoms (large pelvic phantom, uniform head phantom). Effectiveness was measured by calculating the average and maximum error within pairs of ROIs. Results: A non-linearity greater than 50% was observed in the FSRF data. A model calibrated with RSRF data resulted in a significant over-correction of FSRF data. Conversely, models calibrated with FSRF data applied to RSRF data resulted in under-correction. Similar effects were seen when LTI models were applied to data collected at different incident intensities. For CT reconstructions, an average error range of 3-21 HU was achieved when different exposure calibration points were used. Conclusion: Significant non-linear behavior was observed in the FPD. Furthermore, large residual errors remained following LTIM corrections for many calibration setups, and it is unclear how to choose, a priori, the calibration setup that will give the lowest error. A non-LTI correction could potentially describe the panel dynamics and non-linearity more accurately and improve image correction more predictably. Conflict of Interest: This work was supported in part by Varian Medical Systems.
منابع مشابه
An Efficient Ring Artifact Reduction Method Based on Projection Data for Micro-CT Images
Ring artifacts are very troublesome in a flat-panel based micro computed tomography (micro-CT) since they might severely degrade visibility of the micro-CT images. Unlike ring artifacts in other types of micro-CTs such as image-intensifier based micro-CT, ring artifacts in a flat-panel detector based micro-CT are hardly removable since the sensitivity of the pixel elements in a flat-panel detec...
متن کاملLag correction model and ghosting analysis for an indirect‐conversion flat‐panel imager
Cone-beam digital tomosynthesis (CBDT) is a new approach that was recently proposed for rapid tomographic imaging of soft-tissue targets in the radiotherapy treatment room. One of the potential problems in implementing CBDT using, for example, megavoltage (MV) X rays is the possibility of artifacts caused by image lag and ghosting of the X-ray detector used. In the present work, we developed a ...
متن کاملBeam Attenuation Grid–Based Scatter Correction Algorithm for Cone Beam Volume CT
In the flat panel detector-based cone beam CT system, the scatter photons which reach the flat panel detector increase the detected signal, produce the image cupping artifact and reduce the image contrast. To conquer the X-Ray scatter problem, this study proposes the beam attenuation grid -based scatter correction algorithm that needs to add a beam attenuation grid (BAG) between the X-Ray sourc...
متن کاملIn vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)
Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...
متن کاملA Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector
We introduce an efficient ring artifact correction method for a cone-beam computed tomography (CT). In the first step, we correct the defective pixels whose values are close to zero or saturated in the projection domain. In the second step, we compute the mean value at each detector element along the view angle in the sinogram to obtain the one-dimensional (1D) mean vector, and we then compute ...
متن کامل