Evaluation of a glucose oxidase-peroxidase method adapted to the single-channel autoanalyzer and SMA 12-60.
نویسندگان
چکیده
The glucose oxidase-peroxidase method for determining serum glucose, with the ammonium salt of 2,2’-azine-di (3 ethyl benzothiazoline-(6)-sulfonic acid) as the chromogen, was adapted to use with the single-channel AutoAnalyzer and the SMA 12/60 (Technicon Corp.). The extended linearity (up to 500 mg/100 ml on both systems) eliminated the need for numerous dilutions in the 300 to 500 mg/100 ml range as required by other methods of analysis. Recovery of added glucose was excellent. Supranormal concentrations of uric acid and ascorbic acid interfered with recovery, but the effects of elevated bilirubin, creatinine, and urea, and of gross hemolysis were negligible. Sera of 337 patients (glucose concentrations: 50 to 454 mg/100 ml) were analyzed by this method on both instruments and by an automated o-toluidine method. By the latter procedure, the glucose concentration averaged 10 mg/100 ml higher. Sera from uremic patients, measured by the o-toluidine method, had glucose values up to 28.0 mg/100 ml higher than the values obtained by the glucose oxidase method. The glucose oxidase method of measuring serum glucose is a more accurate and precise index of “true glucose” than either the o-toluidine or the neocuproine methods.
منابع مشابه
Evaluation of Trinder's glucose oxidase method for measuring glucose in serum and urine.
Trinder's method for glucose has nearly all the attributes of an ideal automated colorimetric glucose oxidase procedure. The chemicals used in the color reaction with peroxidase are readily available, the solutions are stable and can be prepared by the user, the method is highly specific and largely free of interferences, the sensitivity can be adjusted by the user to cover a wide range of gluc...
متن کاملTable 2 . Precision of Glucose Determination by the Cupric - Neocu proine and Glucose Oxidase
Methodological modifications have been made in our “SMA 12/60 AutoAnalyzer” system, to improve the reproducibility and accuracy of six commonly performed procedures. These include glucose with the glucose oxidase method, albumin with the bromcresol green method, and alkaline phosphatase with the sodium thymolphthalein monophosphate method. We have also modified the composition of the reagents u...
متن کاملEvaluation of the adaptation of the glucose oxidase-peroxidase-3-methyl-2-benzothiazolinone hydrazone-N,N-dimethylaniline procedure to the Technicon "SMA 12-60," and comparison with other automated methods for glucose.
We have evaluated the Technicon SMA 12/60 modification of a glucose oxidase/peroxidase-3-methyl2-benzothiazolinone hydrazone-N, N-dimethylaniline method, and find it acceptable. Added bilirubin, creatinine, dextrans, and uric acid did not interfere. We compared values for patients’ sera by this method to those by the glucose oxidase/peroxidase-2,2’-azinodiethylbenzothiazoline-6-sulfonic acid, n...
متن کاملDirect Automated Determination of Glucose by a Glucose Oxidase-peroxidase System.
THE DETERMINATION of glucose by the glucose oxidase-peroxidase system has been simplified by Hill and Kessler (2) with the use of an automated system first described by Skeggs (1). Wincy and Marks (3) have also developed a method using o-tolidine in the automated system. These procedures require a large quantity of sample and use of a dialyzer to separate the protein before color development. T...
متن کاملDetermination of uric acid on continuous-flow (AutoAnalyzer II and SMA) systems with a uricase/phenol/4-aminophenazone color test.
This report describes a new specific colorimetric procedure for uric acid assay with AutoAnalyzer II and SMA (Technicon) systems, made specific by the application of uricase. Hydrogen preroxide, formed in this reaction, effects the oxidative coupling of 4-aminophenazone and 2,4-dichlorophenol under the catalytic influence of peroxidase. The red dye formed is measured at 505 or 520 nm. A sample ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 19 2 شماره
صفحات -
تاریخ انتشار 1973