A comparative study of simple methods to measure regional cerebral blood flow using iodine-123-IMP SPECT.

نویسندگان

  • M Ohkubo
  • I Odano
  • M Takahashi
چکیده

UNLABELLED The aim of this study was to compare the accuracy and reliability of simple methods of quantifying regional cerebral blood flow (rCBF) with 123I-labeled N-isopropyl-p-iodoamphetamine (IMP) and SPECT and to determine which method was best. METHODS Four methods were examined: (a) the microsphere method with continuous withdrawal of arterial blood, which was based on a microsphere model using the SPECT image obtained 5 min after tracer injection, (b) the microsphere method with one-point sampling, which was the same as the first method except that one-point sampling was used instead of continuous withdrawal, (c) the modified microsphere method with one-point sampling, which was the same as the second method except that a later SPECT image (30-min postinjection) with correction was used and (d) a table look-up method based on a two-compartment model with one-point arterial blood sampling and two SPECT scans obtained 40- and 180-min postinjection. The accuracy of these methods was validated by comparing the rCBF values with those obtained by nonlinear least squares fitting analysis based on the two-compartment model in 15 subjects. RESULTS Regional cerebral blood flow values obtained by the first method correlated most closely with those obtained by nonlinear least squares fitting analysis (error, 6.8%). The second method estimated rCBF with a mean error of 10.4%. The third method estimated rCBF with a mean error of 13.1%, even though it tended to slightly overestimate rCBF. The fourth method was inclined to underestimate rCBF with a mean error of 17.1%, and it greatly overestimated regional distribution volume. CONCLUSION The first method was the most accurate and reliable. For less invasiveness, the first method should be combined with one-point sampling instead of continuous withdrawal, which was used in the second method. When using a delayed SPECT image with a conventional SPECT scanner, the third method was considered to be superior to the fourth method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simplified double-injection method to quantify cerebral blood flow and vascular reserve using iodine-123 IMP-SPECT.

UNLABELLED We developed and evaluated a simplified double-injection method for iodine-123 N-isopropyl-p-iodoamphetamine (IMP) to quantify regional cerebral blood flow (rCBF) twice in a single SPECT session. The method enabled rapid calculations of rCBF with five 10-minute SPECT scans, a fixed distribution volume (Vd), and one-point arterial blood sampling to calibrate a standard input function ...

متن کامل

Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry.

OBJECTIVES Three accumulative tracers, iodine-123-labeled N-isopropyl-p-iodoamphetamine (I-123-IMP), technetium-99m-labeled hexamethylpropyleneamineoxime (Tc-99m-HMPAO), and technetium-99m-labeled ethyl cysteinate dimer (Tc-99m-ECD) are widely used to measure cerebral blood flow (CBF) in single-photon emission computed tomography (SPECT). In the present study, normal regional distribution of CB...

متن کامل

A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method

Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...

متن کامل

Quantitative measurement of regional cerebral blood flow with flow-sensitive alternating inversion recovery imaging: comparison with [iodine 123]-iodoamphetamin single photon emission CT.

BACKGROUND AND PURPOSE Flow-sensitive alternating inversion recovery (FAIR) MR imaging is a technique for depicting cerebral perfusion without contrast enhancement. Our purpose was to determine whether quantification at FAIR imaging can be used to assess regional cerebral blood flow (rCBF) in a manner similar to [iodine 123]-iodoamphetamin ((123)I-IMP) single photon emission CT (SPECT). METHO...

متن کامل

A case of intravascular lymphoma with increased regional cerebral blood flow in I-123 IMP single-photon emission CT.

This report documents a case of intravascular lymphoma (IVL) with increased regional cerebral blood flow (rCBF) disclosed at I-123 IMP single-photon emission CT (IMP-SPECT). A 73-year-old woman with IVL had high rCBF disclosed by IMP-SPECT before chemotherapy; rCBF was normal after one course of CHOP (cyclophophamide, vincristine, doxorubicin, and prednisone) chemotherapy. During her clinical c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 1997