Measurement of human serum ceruloplasmin by its p-phenylenediamine oxidase activity.

نویسندگان

  • F W Sunderman
  • S Nomoto
چکیده

Optimum reaction conditions were evaluated for assay of serum ceruloplasmm by measurement of its p-phenylenediamine oxidase activity. The pH optima of p-phenylenediamine oxidase activities of human and rat ceruloplasmins were 5.45 and 5.2, respectively. The p-phenylenediamine oxidase activity of rat ceruloplasmin was markedly inhibited by phosphate (0.1 mol/Iiter), that of human ceruloplasmin only slightly. These reaction conditions were judged to be optimum for the ceruloplasmin assay: (a) substrate: p-phenylenediamine dihydrochloride, 8.9 mmol/liter; (b) buffer: acetate, 0.1 mol/liter; (c) chloride concentration: 21 mmol/Iiter; (d) serum dilution: 31-fold; (e) incubation: 37#{176}C for 30 mm; (f) spectrophotometry: 530 nm (vs. a “serum blank” containing NaN). Using these reaction conditions, we devised an improved technique for measuring serum ceruloplasmin. The coefficients of variation of replicate analyses by this technique were 1.25% (for “within-run” precision) and 2.8% (for “day-to-day” precision). The mean concentration of ceruloplasmin in sera from 29 healthy men was 0.315 g/Iiter (SD = :t 0.049, range = 0.233to 0.402).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of ceruloplasmin from its oxidase activity in serum by use of o-dianisidine dihydrochloride.

We have developed a new method for determination of serum ceruloplasmin from its oxidase activity, in which o-dianisidine dihydrochioride is used as substrate. o-Dianisidine dihydrochloride is more stable than is the more widely used p-phenylenediamine substrate, and forms a stable product that is measured at 540 nm. Correlation was good between results of this method and those obtained with bo...

متن کامل

Automated measurement of serum ferroxidase activity.

A method is described for automated measurement of serum ceruloplasmin ferroxidase activity. In this method, Fe2+ ions are used as the substrate. In addition, a new calibration system without ceruloplasmin is also presented. Optimum assay reaction conditions were determined. Maximal catalytic activity was obtained at 0.45 mol/L acetate buffer, pH 5.8. The reagents and calibrator are stable for ...

متن کامل

The possible significance of the ferrous oxidase activity of ceruloplasmin in normal human serum.

The oxidation of Fe(I1) by serum was studied at pH 7.35 and at various oxygen concentrations which approach the physiological conditions of human serum. The nonenzymic oxidation of Fe(I1) was estimated to be insufficient to account for a rate of Fe(III)-transferrin formation necessary to provide an adequate iron supply for hemoglobin and other biosyntheses if Fe(I1) is a relevant source of seru...

متن کامل

Automated bichromatic analysis of serum ceruloplasmin.

An automated micromethod is described for measurement of serum ceruloplasmin by assay of its p-phenylenediamine oxidase activity using the Abbott bichoromatic analyzer. Ten mul of serum are mixed with 250 mul of p-phenylenediamine (PPD) substrate (9.2 mmole per liter) in acetate buffer (0.1 mole per liter, pH 5.45). Spectrophotometric measurements of the rate of formation of the purple oxidatio...

متن کامل

Proof for the Ascorbate Oxidase Activity of Ceruloplasmin.

The ascorbate oxidase activity of ceruloplasmin has been a subject of controversy because of (a) the relatively low oxidase activity of this serum copper protein toward ascorbic acid and (b) the different conclusions reached by several investigators. In 1951, Holmberg and Laurel1 (1) reported that ascorbic acid was a substrate of ceruloplasmin although it was less active as a substrate than p-p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 16 11  شماره 

صفحات  -

تاریخ انتشار 1970