Mammotome® biopsy system for the resection of breast lesions: Clinical experience in two high-volume teaching hospitals
نویسندگان
چکیده
Ultrasound-guided vacuum-assisted breast biopsy (VABB) is regarded as a feasible, effective, minimally invasive and safe method for the removal of benign breast lesions, without the occurrence of serious complications. The aim of this study was to evaluate the feasibility, efficacy and safety of ultrasound-guided VABB using the Mammotome® biopsy system in the treatment of breast lesions. The clinical outcomes of 3,681 patients with breast lesions were evaluated following excisions by ultrasound-guided VABB in two high-volume teaching hospitals. From January 2008 to December 2012, a total of 4,867 ultrasound-guided VABB procedures were performed in the 3,681 patients, who had a mean age of 37.8 years (range, 16-73 years). The parameters examined in this analysis included lesion size, lesion location in the inner breast, Breast Imaging Reporting and Data System (BI-RADS) ultrasound category and histopathological diagnosis. Ultrasonography follow-up was performed at 3-6 month intervals in order to assess recurrence. The size of the investigated lesions ranged between 6 and 62 mm and a histopathological diagnosis was made in 100% of cases. The results indicated that the majority of specimens (98.89%) were benign. On average, the ultrasound-guided VABB was performed in 10.3 min (range, 7.5-43 min) and the mean number of cores removed in the procedure was 8.1 (range, 3-32). A complete excision was achieved in the majority of cases (99.7%). The presence of a hematoma was the most common complication following the biopsy, and was observed in 27.5% of patients. The mean follow-up period was 25.5 months (range, 1-60 months), during which the rate of recurrence was 4.4%. The results indicated that ultrasound-guided VABB using the Mammotome biopsy system is an effective and safe procedure that is able to rapidly remove the majority of benign breast lesions using a small incision and without the occurrence of scarring or complications.
منابع مشابه
Ultrasound-guided vacuum-assisted breast biopsy using Mammotome biopsy system for detection of breast cancer: results from two high volume hospitals.
Ultrasound-guided vacuum-assisted breast biopsy (VABB) has been recently regarded as a feasible, effective, minimally invasive and safe method for removal of benign breast lesions without serious complications. The frequency of detection of noninvasive malignant breast lesions by ultrasound-guided VABB is increasing. The aim of this study was to evaluate the role of the ultrasound-guided VABB u...
متن کاملDiagnosis and treatment of breast fibroadenomas by ultrasound-guided vacuum-assisted biopsy.
HYPOTHESIS Ultrasound-guided vacuum-assisted biopsy (UGVAB) can serve as an efficient tool for the diagnosis and excision of breast fibroadenomas. DESIGN Patients with a clinically and radiographically suspected breast fibroadenoma were prospectively referred for UGVAB to confirm the diagnosis and to attempt to excise the lesion. PATIENTS Fifty-two female patients, aged 19 to 68 years, were...
متن کاملVacuum-assisted breast biopsy in nonpalpable solid breast lesions without microcalcifications: the Greek experience.
PURPOSE To present the initial Greek experience with vacuumassisted breast biopsy (VABB) in the diagnosis of nonpalpable solid mammographic lesions without microcalcifications. MATERIALS AND METHODS We performed 83 VABB procedures (using a Fischer table and 11-guage Mammotome probes) in an 18- month period on women with nonpalpable solid breast tumors. We performed VABB procedures on women wi...
متن کاملInitial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device.
OBJECTIVE To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US)-guided, vacuum-assisted breast biopsy (Wi-UVAB) and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions. MATERIALS AND METHODS From March 2013 to October 2014, 114 women (age range, 29-76 years; mean age, 50.0 years) underwent Wi-UVAB using...
متن کاملA comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome® system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions
BACKGROUND Minimally invasive breast biopsy technology is now considered a standard of care for the diagnostic evaluation of suspicious breast lesions. The aim of the current study was to present a comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome(R) system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions. METHODS A retrospective analysis was co...
متن کامل