Perivascular paclitaxel wraps block arteriovenous graft stenosis in a pig model.
نویسندگان
چکیده
BACKGROUND Haemodialysis vascular access dysfunction is currently a huge clinical problem. In an attempt to reduce the morbidity associated with haemodialysis vascular access dysfunction, we have previously developed and validated a local perivascular paclitaxel release system that has been shown to release paclitaxel for at least 3 weeks. The aim of the current study was to evaluate the in vivo use of these perivascular wraps (for both safety and efficacy) at different time points in our pig model of arteriovenous graft stenosis. METHODS Paclitaxel-loaded ethylene vinyl acetate wraps were placed around the graft-vein anastomosis on one side, with control polymers being placed on the contralateral side in our pig model of arteriovenous graft stenosis. Animals were sacrificed at early (10-11 days), middle (23-24 days) and late (32-38 days) time points. The entire graft-vein anastomosis was removed at the time of sacrifice and assessed for the extent of luminal stenosis using histomorphometric techniques. RESULT Graft-vein anastomoses treated with the paclitaxel-loaded polymers had an almost complete absence of luminal stenosis at the middle (23-24 days) and late (32-38 days) time points (when one would expect the development of neointimal hyperplasia) as compared with the contralateral control graft-vein anastomoses (37.90% luminal stenosis in the controls vs 0.10% in the paclitaxel group). There were minimal local side effects from this procedure. CONCLUSIONS Our results demonstrate the safety and efficacy of paclitaxel-loaded perivascular wraps in the setting of a pig model of arteriovenous graft stenosis. We believe that such a local approach which could be easily applied at the time of surgery is ideally suited for use in the clinical setting of haemodialysis vascular access dysfunction. It is likely that this novel approach could result in a significant reduction in the huge economic and health morbidity costs currently associated with this recalcitrant clinical problem.
منابع مشابه
Paclitaxel - a tool to prevent stenosis in vascular access for haemodialysis?
Paclitaxel has an antiproliferative effi cacy against a variety of malignant cell lines and against smooth muscle cells [1, 2] . Hong et al. [3] reported on the placement of paclitaxel-eluting stents to reduce coronary in-stent restenosis in pigs. As an alternative to this ‘inside-out’ drugeluting stent approach, Melhem et al. present an ‘outsidein’ perivascular approach. They could demonstrate...
متن کاملPaclitaxel-coated expanded polytetrafluoroethylene haemodialysis grafts inhibit neointimal hyperplasia in porcine model of graft stenosis.
BACKGROUND The main pathology of haemodialysis graft stenosis is venous neointimal hyperplasia at graft-venous anastomoses. Neointimal hyperplasia is also observed in cases of coronary artery in-stent restenosis. Paclitaxel is a chemotherapeutic agent used to treat cancer, and has been proven to inhibit neointimal hyperplasia of coronary artery in-stent restenosis. In this study, we examined wh...
متن کاملMeasurement of hemodynamic and anatomic parameters in a swine arteriovenous fistula model.
PURPOSE Although arteriovenous fistulae (AVFs) are currently the preferred mode of permanent hemodialysis access they do have significant problems due to initial non-maturation and a later venous stenosis. These problems appear to have been exacerbated following a push to increase AVF prevalence in the US. The reasons for both AVF non-maturation and the later venous stenoses are unclear but are...
متن کاملAdenovirus-mediated expression of beta-adrenergic receptor kinase C-terminus reduces intimal hyperplasia and luminal stenosis of arteriovenous polytetrafluoroethylene grafts in pigs.
BACKGROUND Hemodialysis vascular access dysfunction is the single most important cause of morbidity in kidney hemodialysis patients. Failure of an arteriovenous polytetrafluoroethylene (PTFE) graft, the most common form of hemodialysis access, is primarily due to intimal hyperplasia and thrombosis at the venous anastomosis. METHODS AND RESULTS This study was aimed at evaluating the efficacy a...
متن کاملHemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula.
Venous stenosis is a significant problem in arteriovenous fistulae, likely due to anatomical configuration and wall shear stress profiles. To identify linkages between wall shear stress and the magnitude and pattern of vascular stenosis, we produced curved and straight fistulae in a pig model. A complete wall stress profile was calculated for the curved configuration and correlated with luminal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 21 9 شماره
صفحات -
تاریخ انتشار 2006