Combined fluorescent and interferometric detection of protein on a BioCD.

نویسندگان

  • Xuefeng Wang
  • Ming Zhao
  • D D Nolte
چکیده

We perform simultaneous interferometric and fluorescent detection of molecular protein layers on a BioCD. The 488 nm excitation wavelength of fluorescein also provides the interferometric detection channel that operates in a common-path in-line configuration in the condition of phase quadrature set by a thermal oxide on silicon. The simultaneous acquisition of both channels enables a direct correlation between bound mass and fluorescent surface density, which we compare in forward- and reverse-phase immunoassays. Scaling mass sensitivities for immunoassays measured in the interferometric and fluorescent channels are 15 pg/mm and 1.5 pg/mm, respectively, when applied to gel-printed periodic antibody patterns detected in the frequency domain from the spinning disc. These sensitivities are limited by the inhomogeneities of the print. While fluorescence is subject to bleaching, the interferometry signal is robust under long-term laser illumination.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-speed interferometric detection of label-free immunoassays on the biological compact disc.

BACKGROUND We describe a direct-detection immunoassay that uses high-speed optical interferometry on a biological compact disc (BioCD). METHODS We fabricated phase-contrast BioCDs from 100-mm diameter 1.1-mm thick borosilicate glass disks coated with a 10-layer dielectric stack of Ta2O5/SiO2 that serves as a mirror with a center wavelength at 635 nm. The final layer is a lambda/4 layer of SiO...

متن کامل

Common-path interferometric detection of protein monolayer on the BioCD.

The bio-optical compact disk (BioCD) is an optical biosensor that performs common-path molecular interferometry of patterned proteins on a disk spinning at high speed. The common-path configuration makes it ultrastable and allows surface height precision below 10 pm. In this paper we show that two complementary interferometric quadrature conditions exist simultaneously that convert the modulus ...

متن کامل

Immunofluorescent protein detection in Western blotting

This report describes the detailed procedures for Western blot analysis using fluorescent antibodies. After electrophoresis and subsequent electroblotting, the fluorescent-labeled antibodies were visible upon ultraviolet illumination of the polyvinylidene fluoride (PVDF) membranes and could then be photographed to give an accurate record of the blots. Fluorescent labeling allows for photographi...

متن کامل

Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD

Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning images of printed antibody spots, we quantify the protein sensitivity as a function of the scan parame...

متن کامل

Differential phase-contrast BioCD biosensor.

Common-path differential phase-contrast interferometry measures the spatial gradient of surface dipole density on a bio-optical compact disk (BioCD) and is sensitive to small changes in dipole density following molecular binding of target molecules out of solution. The recognition molecules are antibody IgG proteins that are deposited in periodic patterns on the BioCD using soft lithography or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 47 15  شماره 

صفحات  -

تاریخ انتشار 2008