Relaxometry vs artefact volume measurements for estimating the number of iron-labelled macrophages: in vivo testing in the mouse brain
نویسندگان
چکیده
Rationales and objectives: In recent years, numerous studies have been published on the use of iron oxide nanoparticles for MRI assessment of macrophage infiltration in neuroinflammatory diseases [1]. Quantitative estimate of iron-labelled cells is highly desirable in such studies, as it could allow to monitor the effects of anti-inflammatory drugs. In-vitro studies performed at 4.7T [2] have shown that there was a linear relationship between iron concentration and 1/T2 and 1/T2* for concentrations < 0.36 mM of AMNP, a new class of anionic nanoparticles (CNRS UMR 7612, France) [3]. The aim of this study was to compare four quantitative methods for estimating the number of AMNP-labelled cells stereotaxically implanted in the mouse brain: T2 relaxometry [2], T2* relaxometry [4], and measurement of the volume of the artefact generated by AMNP-labelled cells, using negative and positive contrasts [5]. Materials and Methods: Bone marrow-derived macrophages were incubated in the presence of AMNP ([Fe]=1-mM) for 12h [2]. Eight healthy mice were injected in the striatum with 3-μl saline solution containing a given number of ironlabelled cells ranging from 500 to 7,500 cells (2 injections per mouse, one in each hemisphere). MRI was performed on a Bruker Biospec 4.7T/10-cm magnet, using coronal T2-weighted spin-echo imaging (TE/TR 80/4000-ms), coronal T2*-weighted gradient-echo (T2*GE) imaging (TE/TR 10/30-ms, flip angle 30°, one echo), axial multi-slice multi-echo (MSME) sequence for T2 quantification (TE(interecho delay)/TR 15/4000-ms, 35 echoes) and axial multi-gradient echo (MGE) sequence for T2* quantification (TE/TR 3/450-ms, flip angle 20°, 12 echoes and ΔTE = 5 ms). Two positive contrast images were acquired by shifting the slice rephasing gradient values by ± 20 with regard to the T2*GE sequence [6]: one enhancing the pole of the artefact and one enhancing the equator. These images were then added, and T2*GE was subtracted to improve detection (Combined Positive Contrast CPC). A published methodology was used to estimate cell number based on T2 and T2* quantification, using in vitro calibration curves [2]. The volume of hypointense voxels was measured on all slices of T2*GE images, and the volume of hyperintense voxels was measured on all slices of CPC images. Bland-Altman plots and scatter diagrams were used to compare the T2 and T2*-based estimated number of cells, the artefact volumes, and the actual number of AMNP-labelled cells. Results: Iron-labelled cells were clearly detected on coronal images, with a typical arrowhead artefact on spin-echo images (Fig 1A) and cloverleaf artefact on gradient-echo images (Fig 1B). The pole and equator lobes of the cloverleaf were highlighted in the CPC image (Fig 1C). T2 quantification systematically overestimated the number of AMNP-labelled cells, while T2* quantification underestimated the number of cells in the range [5002500] and overestimated it in the range [5000-7500] (Fig 2A). There was a fair correlation between the number of AMNP-labelled cells and the volume of the artefact for T2*-weighted images (R=0.62) and a good correlation for CPC images (R=0.85) (Fig 2B). Discussion and Conclusion: T2 and T2* quantification failed to estimate the number of AMNP-labelled cell in vivo, while measurement of the artefact volume gave promising results. The impact of different times of echo (TE) on this result remains to be investigated. To our knowledge, these results represent the first obtained in the brain using positive contrast techniques, with a range of cells that is far inferior compared to the literature outside the brain (a few thousands vs hundreds of thousands [5]). Such quantitative approaches should prove useful to enhance the quality of pre-clinical cellular imaging studies. References : [1] Corot et al, Invest Radiol 39, 619 (2004) [2] Brisset et al, Eur Radiol, (2009) [3] Wilhelm et al, Biomaterials 29, 3161 (2008) [4] Politi et al, Stem Cells 25, 2583 (2007) [5] Stuber et al, Magn Reson Med 58, 1072 (2007) [6] Mani et al, Magn Reson Med 55, 126 (2006).
منابع مشابه
Study of histopathological lesions of brain and intestines of Common Carp (Cyprinus carpio) during exposure to iron and zinc oxide nanoparticles
despite of increase in use of metal nanoparticles and their applications in various industries, few studies has been done in vivo on the side effects of this materials, so this research had been done with purpose of effects of nanoparticles of iron and zinc oxide on histopathological changes in brain and intestinal tissues in common carp. For this purpose, first 420 common carp (with an avera...
متن کاملPharmacological Evidences for the Antiamnesic Effects of Desmodium gangeticum in mice
Dementia is one of the age related mental problems and a characteristic symptom of various neurodegenerative disorders including Alzheimer’s disease. Desmodium gangeticum DC. (Leguminosae) is widely used in Ayurveda for treating various neurological disorders. In the present study, the effectiveness of aqueous extract of D. gangeticum in attenuating scopolamine-induced amnesia in mice was inves...
متن کاملPharmacological Evidences for the Antiamnesic Effects of Desmodium gangeticum in mice
Dementia is one of the age related mental problems and a characteristic symptom of various neurodegenerative disorders including Alzheimer’s disease. Desmodium gangeticum DC. (Leguminosae) is widely used in Ayurveda for treating various neurological disorders. In the present study, the effectiveness of aqueous extract of D. gangeticum in attenuating scopolamine-induced amnesia in mice was inves...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملExpression of an Innate Immune Element (Mouse Hepcidin-1) in Baculovirus Expression System and the Comparison of Its Function with Synthetic Human Hepcidin-25
Hepcidin is an innate immune element which decreases the iron absorption from diet and iron releasing from macrophage cell. In contrast to the chemical iron chelators, there has been limited effort applied to the specific use of hepcidin as a new drug for decreasing the iron overload. Hepcidin is produced in different biological systems. For instance, E-coli is used for human hepcidin expressio...
متن کامل