Voxel-level reproducibility assessment of modality independent elastography in a pre-clinical murine model

نویسندگان

  • Katelyn M. Flint
  • Jared A. Weis
  • Thomas E. Yankeelov
  • Michael I. Miga
چکیده

Changes in tissue mechanical properties, measured non-invasively by elastography methods, have been shown to be an important diagnostic tool, particularly for cancer. Tissue elasticity information, tracked over the course of therapy, may be an important prognostic indicator of tumor response to treatment. While many elastography techniques exist, this work reports on the use of a novel form of elastography that uses image texture to reconstruct elastic property distributions in tissue (i.e., a modality independent elastography (MIE) method) within the context of a pre-clinical breast cancer system. 1,2 The elasticity results have previously shown good correlation with independent mechanical testing. 1 Furthermore, MIE has been successfully utilized to localize and characterize lesions in both phantom experiments and simulation experiments with clinical data. 2,3 However, the reproducibility of this method has not been characterized in previous work. The goal of this study is to evaluate voxel-level reproducibility of MIE in a pre-clinical model of breast cancer. Bland-Altman analysis of co-registered repeat MIE scans in this preliminary study showed a reproducibility index of 24.7% (scaled to a percent of maximum stiffness) at the voxel level. As opposed to many reports in the magnetic resonance elastography (MRE) literature that speak to reproducibility measures of the bulk organ, these results establish MIE reproducibility at the voxel level; i.e., the reproducibility of locally-defined mechanical property measurements throughout the tumor volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation and reproducibility assessment of modality independent elastography in a pre-clinical model of breast cancer

Clinical observations have long suggested that cancer progression is accompanied by extracellular matrix remodeling and concomitant increases in mechanical stiffness. Due to the strong association of mechanics and tumor progression, there has been considerable interest in incorporating methodologies to diagnose cancer through the use of mechanical stiffness imaging biomarkers, resulting in comm...

متن کامل

Assessing the accuracy and reproducibility of modality independent elastography in a murine model of breast cancer.

Cancer progression has been linked to mechanics. Therefore, there has been recent interest in developing noninvasive imaging tools for cancer assessment that are sensitive to changes in tissue mechanical properties. We have developed one such method, modality independent elastography (MIE), that estimates the relative elastic properties of tissue by fitting anatomical image volumes acquired bef...

متن کامل

A consistent pre-clinical/clinical elastography approach for assessing tumor mechanical properties in therapeutic systems

Unlike many other experimental imaging methods, elastography has enjoyed a strong link to the standard diagnostic and interventional evaluation technique of soft tissue palpation. As a result, the initial excitement about elastography quickly translated to clinical use (e.g., [1-3]) which now includes commercially available ultrasound and magnetic resonance (MR) elastography products. However, ...

متن کامل

Assessment of transient elastography (FibroScan) for diagnosis of fibrosis in non-alcoholic fatty liver disease: A systematic review and meta-analysis

Background: Transient elastography (TE) is a new modality for the diagnosis of liver fibrosis caused by various etiologies. This study was conducted to determine the accuracy of TE in detecting the different stages of liver fibrosis in non-alcoholic fatty liver disease (NAFLD) patients. Methods: MEDLINE/PubMed, Embase, Ovid, Cochrane Library, American College of Physicians (ACP) Journal Club...

متن کامل

Combined MEG and fMRI model

An integrated model for magnetoencephalography (MEG) and functional Magnetic Resonance Imaging (fMRI) is proposed. In the proposed model, MEG and fMRI outputs are related to the corresponding aspects of neural activities in a voxel. Post synaptic potentials (PSPs) and action potentials (APs) are two main signals generated by neural activities. In the model, both of MEG and fMRI are related to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015