Fatal and nonfatal falls in the construction domain remain a significant issue in todays workforce. The roofing industry in particular, annually ranks amongst the highest in all industries. Exposure to an inclined surface, such as an inclined roof surface, has been reported to have adverse effects on postural stability. The purpose of this preliminary study was to investigate the intra-individual differences in stability parameters on both inclined and level surfaces. Postural Stability (PS) and Limit of Stability (LOS) were assessed in seven healthy subjects (aged 25-35 years) on inclined and level surfaces using embedded force plates and an Inertial Measurement Unit (IMU). Four 90-second trials were collected on the inclined surface in distinctive positions: (1) Toes raised 20o above heel; (2) Heels raised 20o above toes (3); Transverse direction with dominant foot inverted at a lower height; (4) Transverse direction with non-dominant foot inverted at a lower height. Limit of Stability was evaluated by the two measurement devices in all four directions and margin of safety was quantified for each individual on both surfaces. The results reveal significant differences in postural stability between the flat surface condition and the inclined surface condition when subject was positioned perpendicular to the surface slope with one foot descended below the other; specifically, a significant increase was identified when visual support was interrupted. The findings lend support to the literature and will assist in future research regarding early detection of postural imbalance and preventative measures to reduce fall risks in professions where workers are consistently exposed to inclined surfaces.
منابع مشابه
Comparison of intra individual physiological sway complexity from force plate and inertial measurement unit - biomed 2013.
Center of Pressure (COP) is a clinical measure to investigate the effect of sensory input disturbances on postural stability in the healthy, elderly population as well in people suffering from neuromuscular disease. Increased center of pressure velocity and sway area are interpreted as decreased stability or poor balance and are associated with fall risk. Body mounted inertial sensors have show...
متن کاملFall Risk Assessments Based on Postural and Dynamic Stability Using Inertial Measurement Unit
OBJECTIVES Slip and fall accidents in the workplace are one of the top causes of work related fatalities and injuries. Previous studies have indicated that fall risk was related to postural and dynamic stability. However, the usage of this theoretical relationship was limited by laboratory based measuring instruments. The current study proposed a new method for stability assessment by use of in...
متن کاملPostural Stability Analysis with Inertial Measurement Units in Alzheimer's Disease
BACKGROUND The cause of frequent falls in patients with Alzheimer's disease (AD) is still not well understood. Nevertheless, balance control and sensory organization are known to be critical for moving safely and adapting to the environment. METHODS We evaluated postural stability in 20 AD patients (11 fallers and 9 nonfallers) and 16 healthy controls with an inertial measurement unit (triaxi...
متن کاملThe Effect of Non-slippery flooring on Postural Stability and Gait Parameters in Severe Osteoporosis Elderly
Background and Objectives: Investigating the risk factors in osteoporosis elderly to prevent falls and fractures is of high importance. Therefore, this study assesses the effect of different surfaces on postural stability and gait variations in the osteoporosis elderly. Methods: 22 elderlies participated (11 with severe osteoporosis & 11 healthy elderly) in this study in two static and dynam...
متن کاملTest-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups
Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical sciences instrumentation
دوره 49 شماره
صفحات -
تاریخ انتشار 2013