Three phase bone scintigraphy with (99m)Tc-MDP and serological indices in detecting infection after internal fixation in malunion or nonunion traumatic fractures.

نویسندگان

  • Fang Yang
  • Zheng Yang
  • Jin Feng
  • Lianna Zhang
  • Daqing Ma
  • Jigang Yang
چکیده

OBJECTIVE To evaluate the diagnostic efficacy of technetium-99m-methylene diphosphonate ((99m)Tc-MDP) three phase bone scintigraphy in detecting infection in malunion or nonunion traumatic fractures after internal fixation. SUBJECTS AND METHODS One hundred and eighty four patients with malunion or nonunion fractures after internal fixation (130 men and 54 women; age range, 16-79 years) underwent (99m)Tc-MDP three phase bone scintigraphy (3PBS). They were divided into the infection group (n=96) and the control group without infection (n=88) based on the final diagnosis after operation. The sensitivity, specificity, accuracy, positive prediction value (PPV) and negative prediction value (NPV) were calculated and compared. All patients carried out other laboratory tests related to infection such as complete serum blood cells count, C-reactive protein (CRP), and erythrocyte sedimentation rate (ESR). RESULTS The (99m)Tc-MDP 3PBS for the blood flow phase showed sensitivity, specificity, accuracy, positive predictive value and negative predictive value, 91.7% (88/96), 72.7% (64/88), 82.6% (152/184), 78.6% (88/112) and 88.9% (64/72), respectively and for the blood pool phase, 93.8% (90/96), 61.4% (54/88), 78.3% (144/184), 72.6% (90/124) and 90.0% (54/60) respectively. The semiquantitative indices of the ratio between the abnormal and the normal region of interest (ROI), called by us the A/N ratio, for both blood flow and blood pool phases as estimated between the infection group and the control group were statistically different. CONCLUSION It is the opinion of the authors that (99m)Tc-MDP 3PBS provided high predictive values in diagnosing infection in patients with malunion or nonunion traumatic fractures after internal fixation. The diagnostic value of blood flow and blood pool phases estimated of the 3PBS was better than the laboratory indices: white blood cell counts, CRP, and ESR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidental thyroid uptake during 99mTc-methylene diphosphonate bone scintigraphy in oncologic patients

Introduction: Extraosseous accumulation of 99mTc – methylene diphosphonate (MDP) may be due to neoplastic, dystrophic, hormonal, inflammatory, ischemic, traumatic or excretory disorders. 99mTc-MDP incidental thyroid uptake is not frequent and is possibly caused by the presence of dystrophic or metastatic calcification, biopsy procedure and presence of beni...

متن کامل

Is 99m Tc-methylene diphosphonate bone scintigraphy a sensitive method for detecting bone lesions in multiple myeloma?

Background: Bone lesion in multiple myeloma (MM) is most commonly presented as a lytic lesion in this disease. Determination of extent of bone lesions in MM is necessary to follow-up the patients. Whole body bone scan with 99m, Tc-methylene diphosphonate (MDP) has a lower sensitivity than other modalities. Methods: From the patients with MM admitted to Ayatollah Rouhani Hospital of Babol-Iran ...

متن کامل

Tc-UBI 29-41 Scintigraphy Imaging in Preferentially Detection Infection from Sterile Inflammation among Diabetic Patients with Suspected Foot Infection

Ubiquicidin 29-41 (UBI 29-41) is an antimicrobial peptide with six positively charged residues which preferentially binds to the negatively charged groups present on the microbial membrane by electrostatic interaction at the foci of infection. For this reason UBI 29-41 has been suggested to label by 99m Tc ( 99m Tc-UBI 2941)directly or by using coligand reagents like 6-hydrazinopyridine 3-carbo...

متن کامل

Sternal nonunion on bone scintigraphy: a case report

Sternal non-union is a severe complication of sternotomy closure following open heart surgeries. Healing problems typically occur in 0.3% to 5% of patients. Technetium-99m methylene diphosphonate (99mTc-MDP) bone scintigraphy has been used to assess bone nonunion to predict the healing response for proper management.  In this report, we present the case of a marked sternal nonunio...

متن کامل

The effect of prednisolone on the sensitivity of Technetium 99m-methylene diphosphonate ( 99m Tc-MDP) scintigraphy to detect simulated closed fracture in the rat tibia

Introduction: The purpose of the present study was to evaluate the effect of prednisolone on the sensitivity of bone scanning to detect the simulated closed fracture in the rat tibia.  Methods: A total number of forty eight adult, male NMRI rats randomly assigned into two parts, one part for 4 and other for 8 weeks experiments. Each part has been divided into four groups, one group not receivi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of nuclear medicine

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2016