Low Intensity Beam Diagnostics with Microchannel Plate Detectors

نویسندگان

  • G. Cuttone
  • C. De Martinis
  • P. Finocchiaro
  • D. Giove
  • G. Raia
  • A. Rovelli
چکیده

A non destructive low intensity ion beam profile monitor has been designed and tested. The system is based on a MCP that detects the residual gas ionization produced by the ion beam. The detector is coupled to a phosphorous screen for the readout of the vertical and horizontal density profiles. Experimental results have shown that the system is able to detect beam intensities as low as 10 pps with a local vacuum in the measuring box of the order of 8x10 mbar. In the paper we report the results so far obtained in beam sensitivity and measure precision as a function of the residual pressure and in different regimes of the detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross Strip Anode Imaging Readouts for Microchannel Plate Detectors

We have developed a novel microchannel plate readout scheme, the cross strip anode. The cross strip anode has a coarse (0.5mm) multilayer metal and ceramic cross strip pattern that encodes event positions by direct sensing of the charge on each strip and subsequent determination of the charge cloud centroid for each event. Event position encoding is accomplished with chip level preamplifiers on...

متن کامل

Recent Developments in Ultra-High Speed and Large Area Photomultiplier Tubes

Photek has been working with AWE to provide photomultiplier (PMT) solutions for fusion diagnostics. By using microchannel plates (MCP) as the gain medium, the time response of the PMTs can be as fast as 100 ps FWHM. We will present data showing developments in the accurate measurement of the true impulse response of the fastest detectors. We will also show improvements in the pulse uniformity a...

متن کامل

Beam test of a Time-of-Flight detector prototype

We report on results of a Time-of-Flight, TOF, counter prototype in beam tests at SLAC and Fermilab. Using two identical 64-pixel Photonis Microchannel Plate Photomultipliers, MCP-PMTs, to provide start and stop signals, each having a 1 cm-long quartz Cherenkov radiator, we have achieved a timing resolution of σSingle_detector ~14 ps. To be published in Nucl. Instr.& Methods ——— • Manuscript re...

متن کامل

Microchannel plate cross-strip detectors with high spatial and temporal resolution.

The cross-strip imaging readout employs charge division, and centroiding, of microchannel plate charge signals detected on two orthogonal layers of sense strips to encode event X-Y positions and times. We have developed cross-strip detectors and fully parallel channel position encoding electronics. The front-end amplifiers utilize two 32-channel pre-amplifier ASICs that send signals to a full 6...

متن کامل

The On-orbit Performance of the Galaxy Evolution Explorer

We report the first year on-orbit performance results for the Galaxy Evolution Explorer (GALEX), a NASA Small Explorer that is performing a survey of the sky in two ultraviolet bands. The instrument comprises a 50 cm diameter modified Ritchey-Chrétien telescope with a 1.25 field of view, selectable imaging and objective grism spectroscopic modes, and an innovative optical system with a thin-fil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998