Balloon angioplasty of aortocoronary saphenous vein bypass grafts: a histopathologic study of six grafts from five patients, with emphasis on restenosis and embolic complications.

نویسندگان

  • R S Saber
  • W D Edwards
  • D R Holmes
  • R E Vlietstra
  • G S Reeder
چکیده

Among 103 patients undergoing percutaneous transluminal balloon angioplasty of obstructed aortocoronary saphenous vein bypass grafts at the Mayo Clinic, six grafts from 5 patients were available for histopathologic examination. The interval from graft insertion to angioplasty ranged from 5 to 105 months and that from angioplasty to graft excision ranged from 6 h to 24 months. Angioplasty produced intimal fissures in three grafts initially obstructed by intimal fibromuscular proliferation. Healing and restenosis resulted from filling of lacerations with fibrocellular tissue and apparently also from restitution of muscular tone. In two of three grafts initially narrowed by atherosclerosis, balloon angioplasty cause extensive plaque rupture and restenosis resulted from extrusion of plaque debris and secondary luminal thrombosis. In the third graft, angioplasty produced no distinct lesions and late restenosis was due to progressive atherosclerosis of the vein graft. Atheroembolization was observed in both patients with plaque rupture and was associated with reoperation in one and death in the other. In conclusion, the results derived from six saphenous vein bypass grafts subjected to balloon angioplasty indicate that restenosis may result from intimal fibrocellular proliferation, thrombosis, restitution of muscular tone and progressive atherosclerosis. Symptomatic atheroembolization may occur in grafts greater than 1 year old.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. Saphenous Vein De Novo Trial Investigators.

BACKGROUND Treatment of stenosis in saphenous-vein grafts after coronary-artery bypass surgery is a difficult challenge. The purpose of this study was to compare the effects of stent placement with those of balloon angioplasty on clinical and angiographic outcomes in patients with obstructive disease of saphenous-vein grafts. METHODS A total of 220 patients with new lesions in aortocoronary-v...

متن کامل

Clinical experience with the Wiktor stent in native coronary arteries and coronary bypass grafts.

OBJECTIVES To evaluate the results of implantation of Wiktor tantalum wire coronary stents in stenosed or occluded coronary vessels or in saphenous vein bypass grafts. DESIGN A retrospective analysis of clinical and angiographic data from patients treated with tantalum wire stents implanted by one operator at two centres. PATIENTS 52 patients undergoing conventional balloon angioplasty had ...

متن کامل

Initial experience with excimer laser angioplasty for coronary ostial stenoses.

The excimer laser has several potential advantages over conventional balloon angioplasty in the management of stenoses of the native coronary arteries and of the ostia of saphenous vein grafts. Its use in nine patients, eight of whom were classed as high risk, is described. Four lesions involved the ostia of saphenous vein grafts, three of protected left main stems, and two of native right coro...

متن کامل

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.

BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...

متن کامل

Radial artery versus saphenous vein patency randomized trial: five-year angiographic follow-up.

BACKGROUND Graft patency is a fundamental predictor of long-term survival after coronary artery bypass surgery. Left and right internal thoracic artery (arterial) graft patency has been shown to be superior to that of saphenous vein grafts. More recently, the radial artery has been used as an aortocoronary graft, but little is known about the midterm and long-term patency of this conduit. We pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 1988