Comparison of a fluorometric assay kit with high-performance liquid chromatography for the assessment of serum retinol concentration.

نویسندگان

  • Aglago Kouassivi Elom
  • El Menchawy Imane
  • Benjeddou Kaoutar
  • El Kari Khalid
  • El Hamdouchi Asmaa
  • Azlaf Mehdi
  • El Haloui Noureddine
  • Aguenaou Hassan
چکیده

BACKGROUND Although high-performance liquid chromatography (HPLC) is the commonly used method for the analysis of retinol in biological samples, simple and rapid test kits are available. OBJECTIVES This study compared a rapid test kit (ICHECK Fluoro®) to HPLC for the assessment of serum retinol concentrations. METHODS For the analysis by HPLC, sample preparation included standard deproteinization and extraction phases. The analysis by ICHECK was performed by injecting serum into IEX reagent vials (n=89) and mixing manually for separation. After precipitation of the proteins, the vial was introduced into the chamber of the ICHECK Fluoro and analysed at 0 min (ICHECK0min) and 15 min later (ICHECK15min). Bland and Altman approach was applied to test the agreement between HPLC and ICHECK. RESULTS Mean HPLC, ICHECK0min and ICHECK15min values were 421.2±106.0 µg/L, 423.1±118.3 µg/L and 413.2±107.6 µg/L, respectively. Retinol concentrations significantly decreased in the IEX solution over time (p<0.001). No significant proportional bias was observed between HPLC and ICHECK0min (r-0.038, p=0.73) and ICHECK15min (r=-0.024, p=0.82). Fixed biases (HPLC minus ICHECK) for ICHECK0min and ICHECK15min were respectively -1.9±23.1 µg/l (p=0.45) and 8.0±22.7 µg/l (p=0.002). CONCLUSION ICHECK Fluoro may offer a reliable mean for assessing serum retinol for measurements performed with no significant time delay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

بکارگیری کروماتوگرافی مایع با کارکرد بالا

World health organization has introduced concentration of vitamin A in breast milk as a proper indicator for characterization of vitamin A deficiency in lactating mothers and their infants (<6 mo). A normal phase high performance liquid chromatography with spectrofluorometric detection as a specific and sensitive detector was used for characterization of all-trans retional from 13-Cis retinal. ...

متن کامل

Evaluation of a direct fluorometric method for determination of serum retinol.

We evaluated the usefulness of a fluorometric method for determining serum retinol (Futterman et al., Invest Ophthalmol Vis Sci 1975;14:125-30) in which fluorescence (excitation 335 nm; emission 460 nm) of retinol is directly measured in unextracted, diluted serum. Using serum from 466 individual donors, we compared values so obtained with those by a "high-performance" liquid-chromatographic me...

متن کامل

Proxy markers of serum retinol concentration, used alone and in combination, to assess population vitamin A status in Kenyan children: a cross-sectional study

BACKGROUND Serum retinol concentration determined by high-performance liquid chromatography (HPLC) is recommended by the World Health Organization to assess population vitamin A status. This assay is expensive, technically demanding and rarely available in developing countries. Our objective was a) to assess the diagnostic performance of proxy markers in detecting vitamin A deficiency and b) to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • African health sciences

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2015