A neonate with bilateral corneal opacities and glaucoma.

نویسندگان

  • Hitesh Agrawal
  • Sachin K Gupta
  • Gunjan Dokania
  • Philip B Dray
  • Ahmad A Aref
  • Aisha Traish
  • Richard J David
چکیده

, 62 Aterm male neonate born via normal delivery to an AfricanAmerican woman at 39 weeks gestation presented with bilateral corneal clouding. The anthropometric measurements were all < 10% for gestational age (birth weight of 2239 g, head circumference of 31 cm, and length of 46 cm). A cephalhematoma measuring approximately 3 cm × 3 cm was present on right parietal area. Laboratory studies revealed a white blood cell count of 13,300/mm3 with

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transplantation of congenitally opaque corneas.

AIMS To assess retrospectively the prognosis and complications of corneal grafting for congenital opacities. METHODS Fifty eight eyes of infants and young children with congenital corneal opacities were studied retrospectively. Preoperative diagnoses included sclerocornea (27 eyes), Peters' anomaly (17 eyes), partial sclerocornea (12 eyes), and congenital glaucoma (two eyes). Penetrating kera...

متن کامل

Pre-descemetic corneal dystrophy.

Maeder and Datiis (1947) described a 40-year-old woman with small white curved filaments occupying a disc in the deepest layers of the corneal stroma. The peripheral 2 mm. of cornea remained unaffected. The corneae of this patient showed keratoconus, clinically manifest in the left eye with a forme fruste in the right. D'Ermo (1950) annotated a similar case in a 19-year-old girl who was also af...

متن کامل

An Unusual Presentation of Corneal Perforation in a Neonate Following Instrument-Assisted Delivery

A 25-week-old neonate was noted to have unilateral corneal edema and buphthalmos at birth following a forceps assisted delivery. Ten days later, examination of the neonate under anesthesia showed a central corneal perforation with a possible retinal detachment. By this time the neonate’s affected eye was deemed unsalvageable, and therefore an enucleation was performed with insertion of an ocula...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Corneal opacities--a diagnostic feature of the trisomy 8 mosaic syndrome.

An infant with trisomy 8 mosaicism had bilateral corneal opacities and multiple systemic anomalies. A review of the literature suggests that corneal opacities are a prominent feature of the syndrome and may have substantial clinical and diagnostic importance.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric annals

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2014