Bus Priority Ranking via Stability Index Tracing and Evolutionary Programming

نویسنده

  • N. A. RAHIM
چکیده

There are various methods applied for indicating the most sensitive bus for any corrective and preventive actions like power scheduling at generation site and shunt element placement such as capacitor bank and FACTS devices at load site. The methods can be sensitivity analysis, optimization method, stability index based ranking and lastly the method that is rarely applied, termed as power tracing. Currently, the usage of power tracing technique is majorly limited to the field of transmission service pricing although there are various methods that have been developed by researchers. By virtue of that, this paper promotes a new technique for identifying the most suitable generator bus to be performed power scheduling and the best load bus for shunt element installation by means of Fast Voltage Stability Index Tracing (FVSI-T) via Evolutionary Programming (EP). Validation on IEEE 14-Bus and 57-Bus reliability test system (RTS) revealed that the proposed method has great capability to be applied into real system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applying the Fvsi-generation Tracing and Hybrid Ant Colony Algorithm for Effective Static Generation Power Dispatch

This paper proposes the latest application of power tracing technique for voltage stability improvement. Instead of solving losses charge allocation problem in deregulated power market as performed by many researchers, the proposed technique can be implemented for effective static generation power dispatch; that is, by determining suitable generating units involved in re-dispatching with the ai...

متن کامل

Effective transient stability assessment based on composite indices

This paper presents a new composite index to analyze power system transient stability. Contingency ranking in power system transient stability is a complicated and time consuming task. To prevail over this difficulty, various indices are used. These indices are based on the concept of coherency, transient energy conversion between kinetic and potential energy and three dot products of the s...

متن کامل

Voltage Stability Constrained OPF Using A Bilevel Programming Technique

This paper presents a voltage stability constrained optimal power flow that is expressed via a bilevel programming framework. The inner objective function is dedicated for maximizing voltage stability margin while the outer objective function is focused on minimization of total production cost of thermal units. The original two stage problem is converted to a single level optimization problem v...

متن کامل

Fuzzy Approach to Contingency Ranking

The contingencies contribute to overloading of network branches and unsatisfactory voltages, which may lead to problems of stability/voltage collapse. The most important task in security analysis is the problem of identifying the critical contingencies from a large list of credible contingencies and rank them according to their severity. This paper presents fuzzy approach for ranking the contin...

متن کامل

Weakest Buses Identification and Ranking in Large Power Transmission Network by Optimal Location of Reactive Power Supports

The detection of voltage collapse is essential to avoid possible voltage collapse for the preventive control actions and voltage security assessment. One effective way to know the locations where voltage collapses could be appear is to identify weakest buses in the systems. The weakest bus is the first point where voltage collapses appear in a severe contingency. This paper proposes a technique...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012