In-vitro method for assessing femoral implant-bone micromotions in resurfacing hip implants under different loading conditions.

نویسندگان

  • L Cristofolini
  • E Varini
  • M Viceconti
چکیده

Although prosthesis-bone micromotion is known to influence the stability of total hip replacement, no protocol exists to investigate resurfacing hip implants. An in-vitro protocol was developed to measure prosthesis-bone micromotions of resurfaced femurs. In order to assess the effect of all loading directions, the protocol included a variety of in-vitro loading scenarios covering the range of directions spanned by the hip resultant force in the most typical motor tasks. Gap-opening and shear-slippage micromotions were measured in the locations where they reach the maximum value. The applicability of the protocol was assessed on two commercial designs and different head sizes. Intra-specimen repeatability and inter-specimen reproducibility were excellent (comparable with the best protocols for cemented hip stems). Results showed that the protocol is accurate enough to detect prosthesis-bone micromotions of the order of a few microns. Statistically significant differences were observed in relation to the direction of the applied force. Using the whole range of hip loads enabled detection of maximum micromotions for any design (the peak value could be different for different loading directions). Application of the protocol during a test to failure indicated that the system could track micromotion up to the last instant prior to failure. The protocol proposed is thus completely validated and can be applied for preliminary screening of new epiphyseal designs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Biomechanics of the Birmingham hip resurfacing arthroplasty.

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison o...

متن کامل

Position of hip resurfacing component affects strain and resistance to fracture in the femoral neck.

BACKGROUND Retrieval studies have suggested that the cause of femoral implant failure after metal-on-metal hip resurfacing is multifactorial. Both varus positioning of the femoral component and notching of the superior part of the femoral neck have been associated with femoral component failure. The hypotheses of this study were that placement of a femoral resurfacing component alters femoral n...

متن کامل

[The bending rod prosthesis: an experimental approach to metaphyseal hip arthroplasty].

The aim of our study was to develop a femoral component for total hip arthroplasty that would exclusively anchor in the metaphysis of the femoral neck. To forego trochanteric fixation, the load needs to be transferred to the metaphysis at as many points as possible. A computer simulation model suggested that an implant with a central cylinder and 16 rods aligned along a thread would be the pref...

متن کامل

Functional interface micromechanics of 11 en-bloc retrieved cemented femoral hip replacements

BACKGROUND AND PURPOSE Despite the longstanding use of micromotion as a measure of implant stability, direct measurement of the micromechanics of implant/bone interfaces from en bloc human retrievals has not been performed. The purpose of this study was to determine the stem-cement and cement-bone micromechanics of functionally loaded, en-bloc retrieved, cemented femoral hip components. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 221 8  شماره 

صفحات  -

تاریخ انتشار 2007