A bubble-gating flow cell for continuous-flow analysis.
نویسندگان
چکیده
A system is described which permits measurements,such as photometry, to be made on air-segmented streams, as in continuous-flow analysis. Elimination of -the “debubbler” step before measurement provides two basic assets: (1) more rapid attainment of steady-state conditions (lower interaction between samples), and (2) maintenance of the integrity of the bubbled analysis stream, permitting subsequent handling and remeasurement.A device has been developed for detecting air bubbles. When placed acrossthe light path of a photometer flow cell it inactivates the readout system when bubbles pass by. The resulting system measures the transmittance of each individual liquid segment of the analysisstream, while maintaining the integrity of the stream. Two examples of possibleapplications of this system are described. One is a simple total-protein determination with biuret, at three times the conventional sampling rate. The other is a continuous-flow, two-point, reaction-rate method for assayof alkaline phosphataseactivity.
منابع مشابه
CFD Hydrodynamics Analysis of Syngas Flow in Slurry Bubble Column
In this paper, a CFD model of syngas flow in slurry bubble column was developed. The model is based on an Eulerian-Eulerian approach and includes three phases: slurry of solid particles suspended in paraffin oil and syngas bubbles. Numerical calculations carried out for catalyst particles, bubble coalescence and breakup included bubble-fluid drag force and interfacial area effects. Also, the ef...
متن کاملNumerical Analysis of Water and Air in Venturi Tube to Produce Micro-Bubbles
Two-phase flow regimes are affected by conduit position, alignment, geometry, flow direction, physical characteristics, and flow rate of each phase as well as the heat flux toward the boundaries. Due to the importance of two-phase flow, numerous regimes have been identified. The first step in studying micro-bubble formation inside a venturi tube is to recognize the type of flow regimes. In this...
متن کاملEvaluation of Recirculation Time in Bubble Train Flow by Using Direct Numerical Simulation
In this research, hydrodynamics of the Bubble Train Flows (BTF) in circular capillaries has been investigated by Direct Numerical Simulation (DNS).The Volume of Fluid Based (VOF) interface tracking method and streamwise direction periodic boundary conditions has been applied. The results show that there exists an appropriate agreement between DNS and experimental correlation results. The re...
متن کاملAnalysis of Pseudo-Turbulence Flow Induced by Bubble Periodic Formation in Non-Newtonian Fluids
Laser Doppler Velocimetry (LDV) has been employed to determine pseudo-turbulence characteristics of the flow field around bubble train forming in non-Newtonian caboxymethylcellulose (CMC) aqueous solution at low gas flow rate condition. The Reynolds stress and turbulent intensity of the liquid were investigated by means of Reynolds time-averaged method. The experimental results show that ax...
متن کاملExperimental investigation of bubble growth and detachment in stagnant liquid column using image – based analysis
An experimental study has been carried out to characterize bubble formation, growth, and detachment mechanisms in a stagnant liquid column. Both bubble frequency and bubble detachment size were measured in different gas flow rates, injector diameters and orientations, submergence height, and liquid properties. Experiments were performed for air injection flow rate ranges between 200 mlph and 12...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 15 11 شماره
صفحات -
تاریخ انتشار 1969