Staphylococcus aureus biofilm formation on different gentamicin-loaded polymethylmethacrylate bone cements.
نویسندگان
چکیده
In this in vitro study, the formation of a Staphylococcus aureus biofilm on six gentamicin-loaded bone cements (CMW1, CMW3, CMW Endurance, CMW2000, Palacos, and Palamed) was determined in a modified Robbins device over a 3 days time span and related with previously (Van de Belt et al., Biomaterials 21 (2000) 1981) measured kinetics of antibiotic release by these cement brands. The influence of gentamicin release on biofilm formation was quantified by expressing the number of colony-forming units on gentamicin-loaded cement relative to the number of viable organisms on unloaded cement of the same brand. Biofilms formed on all gentamicin-loaded cements, despite the release of antibiotics, followed a consistent pattern in time with a maximum number of colony-forming units per unit cement area found between 24 and 30 h after inoculation. None of the gentamicin-loaded cements showed a reduction in biofilm formation relative to unloaded cements within 6 h after inoculation, whereas only gentamicin-loaded CMW1 and Palacos reduced biofilm formation 24 h after inoculation. Alternatively, CMW Endurance, CMW2000, and Palamed did not exhibit any initial reductions in biofilm formation, but effects started after 72, 48, and 72 h, respectively. Biofilm reduction by gentamicin-loaded CMW3 lasted the longest from 24 to 72 h. Interestingly, each cement seemed to have a different "window-of-effectiveness" with regard to reduction in biofilm formation that did not relate with the gentamicin-release kinetics. Summarising, this study demonstrates that although gentamicin loading of bone cements yields reductions in biofilm formation, S. aureus is able to grow on gentamicin-loaded bone cements.
منابع مشابه
Gentamicin release from polymethylmethacrylate bone cements and Staphylococcus aureus biofilm formation.
We measured the formation of a Staphylococcus aureus biofilm in vitro on unloaded and gentamicin-loaded bone cements (CMW3 and Palacos R) and related the formation to antibiotic release rates. All experiments were done in triplicate. Microbial growth on gentamicin-loaded cements occurred despite the release of antibiotic. Biofilm formation on gentamicin loaded CMW3 bone cement was one fourth to...
متن کاملCopal Bone Cement Is More Effective in Preventing Biofilm Formation than Palacos R-G
Bone cements loaded with combinations of antibiotics are assumed more effective in preventing infection than bone cements with gentamicin as a single drug. Moreover, loading with an additional antibiotic may increase interconnectivity between antibiotic particles to enhance release. We hypothesize addition of clindamycin to a gentamicin-loaded cement yields higher antibiotic release and causes ...
متن کاملFormation of Propionibacterium acnes biofilms on orthopaedic biomaterials and their susceptibility to antimicrobials.
Failure to treat and eradicate prosthetic hip infection with systemic antibiotic regimens is usually due to the fact that the infection is associated with biofilm formation and that bacterial cells growing within a biofilm exhibit increased resistance to antimicrobial agents. In this in vitro study, we investigated the susceptibility of prosthetic hip Propionibacterium acnes and Staphylococcus ...
متن کاملGentamicin in bone cement
OBJECTIVES The objective of this study is to determine an optimal antibiotic-loaded bone cement (ALBC) for infection prophylaxis in total joint arthroplasty (TJA). METHODS We evaluated the antibacterial effects of polymethylmethacrylate (PMMA) bone cements loaded with vancomycin, teicoplanin, ceftazidime, imipenem, piperacillin, gentamicin, and tobramycin against methicillin-sensitive Staphyl...
متن کاملIn vitro testing of gentamicin-vancomycin loaded bone cement to prevent prosthetic joint infection.
Sepsis is a greatly feared complication of total joint arthroplasty. One key question is how to prevent perioperative bacterial adherence, and therefore the potential for infectious complications. The objective of our study was to appraise the emerging capacity of staphylococcal survival on prosthetic materials and to analyze the in vitro effects of gentamicin and vancomycin loaded polymethylme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomaterials
دوره 22 12 شماره
صفحات -
تاریخ انتشار 2001