LC-MS/MS Analysis of Canine Lipoproteins Fractionated Using the Ultracentrifugation-Precipitation Method

نویسندگان

  • Asuka SUTO
  • Masahiro YAMASAKI
  • Yukari TAKASAKI
  • Yasuyuki FUJITA
  • Riichiro ABE
  • Hiroshi SHIMIZU
  • Hiroshi OHTA
  • Mitsuyoshi TAKIGUCHI
چکیده

Due to the lack of a gold standard method in canine lipoprotein analysis, it is unclear whether canine high-density lipoprotein (HDL) and low-density lipoprotein (LDL) can be accurately evaluated by the lipoprotein analysis methods used for dogs. This study investigated whether the ultracentrifugation-precipitation (U-P) method was suitable as a gold standard method for analyzing canine lipoprotein. First, the U-P method was compared with a gel permeation high-performance liquid chromatography system (GP-HPLC). The concentrations of canine HDL cholesterol (HDL-C) and LDL cholesterol (LDL-C) determined by the U-P method correlated closely with those determined by GP-HPLC. However, the canine HDL-C concentration determined by the U-P method was lower than that determined by GP-HPLC, and the canine LDL-C concentration determined by the U-P method was higher than that determined by GP-HPLC. This study showed that some canine HDL could be precipitated with heparin manganese chloride solution. Second, the HDL and LDL fractions separated by the U-P method were analyzed by LC-MS/MS. The HDL fraction was found to contain only apolipoprotein A-I, which is an apolipoprotein of HDL, whereas the LDL fraction contained both apolipoprotein A-I and apolipoprotein B-100, which is an apolipoprotein of LDL. This data showed that a certain lipoprotein that includes apolipoprotein A-I might precipitate with canine LDL when using heparin manganese chloride solution. These results indicated that the U-P method is not currently a gold standard method for analyzing canine lipoproteins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market

For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...

متن کامل

Antibody-free workflows for protein quantification by LC-MS/MS.

Antibody-free approaches for quantitative LC-MS/MS-based protein bioanalysis are reviewed and critically evaluated, and compared with the more widely used immunoaffinity-based approaches. Antibody-free workflows will be divided into four groups and discussed in the following order: direct analysis of signature peptides after proteolytic digestion; enrichment of target proteins and signature pep...

متن کامل

Method development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market

For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...

متن کامل

LC-MS/MS Method for Serum Creatinine: Comparison with Enzymatic Method and Jaffe Method

Accurate quantification of creatinine (Cre) is important to estimate glomerular filtration rate (GFR). Differences among various methods of Cre quantification were previously noted. This study aims to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for serum Cre and compare this method with clinical routine methods. LC-MS/MS analysis was performed on API 4000 triple q...

متن کامل

Validation of the analysis method of 25 pesticide residues in rice using LC-MS/MS device (liquid chromatography-mass spectrometry)

Introduction: In recent years, due to the increase in the use of pesticides in agricultural products and its entry into the human food chain, there has been an increase in concerns about the health of food among people. Therefore, the purpose of conducting this research is to validate the analysis method. 25 pesticide residues in rice using LC-MS/MS. Methods: In this research, a simultaneous an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013