Airborne measurement of inorganic ionic components of fine aerosol particles using the particle-into-liquid sampler coupled to ion chromatography technique during ACE-Asia and TRACE-P

نویسندگان

  • Y.-N. Lee
  • R. Weber
  • Y. Ma
  • D. Orsini
  • K. Maxwell-Meier
  • D. Blake
  • S. Meinardi
  • G. Sachse
  • C. Harward
  • T.-Y. Chen
  • D. Thornton
  • F.-H. Tu
  • A. Bandy
چکیده

[1] Eight inorganic ions in fine aerosol particles (Dp < 1.3 mm) were measured on board the NCAR C130 and NASA P-3B aircraft during the 2001 Aerosol Characterization Experiment (ACE)-Asia and the Transport and Chemical Evolution over the Pacific (TRACE-P) experiments, respectively. Concentrations of NH4 , SO4 2 , NO3 , Ca, K, Mg, Na, and Cl were determined using a particle-into-liquid sampler coupled to ion chromatography (PILS-IC) technique at a 4-min resolution and a limit of detection <0.05 mg m . The maximum total ion concentrations observed on the C130 and the P-3B were 27 mg m 3 and 84 mg m , respectively. During ACE-Asia, NH4 + and SO4 2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dust composition and mixing state inferred from airborne composition measurements during ACE-Asia C130 Flight #6

In this study 3.5min average bulk aerosol composition data recorded from aircraft during ACE-ASIA C130 Flight #6 are used to investigate the extent of fine particle (Dp 50 o 1.3mm) mixing among various inorganic aerosol particle constituents. Dust-laden air masses that had mixed with urban air pollutants over the Beijing and Tianjin region were subsequently recorded in the marine boundary layer...

متن کامل

Intercomparison of airborne and surfacebased measurements of condensation nuclei in the remote marine troposphere during ACE 1

Intercomparisons of aerosol particle number concentrations measured with various condensation particle counters (CPCs) during the first Aerosol Characterization Experiment (ACE 1) are made to assess the accuracy of the airborne measurements. When no ambient 3-10 nm diameter particles (nanoparticles) were present, median concentrations from four CPCs on the National Center for Atmospheric Resear...

متن کامل

Trace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography

For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...

متن کامل

Trace determination of gatifloxacin in pharmaceutical and biological samples using hydrophobic magnetic nanoparticles-assisted ionic liquid microextraction coupled with spectrofluorimetry

A simple and rapid microextraction procedure based on the application of magnetic nanoparticles and hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL) was applied to trace determination of gatifloxacin. A mixture of [Hpy][PF6] and magnetic nanoparticles was injected into the sample solution containing the analyse of interest and a cloudy solution was forme...

متن کامل

Trace determination of gatifloxacin in pharmaceutical and biological samples using hydrophobic magnetic nanoparticles-assisted ionic liquid microextraction coupled with spectrofluorimetry

A simple and rapid microextraction procedure based on the application of magnetic nanoparticles and hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL) was applied to trace determination of gatifloxacin. A mixture of [Hpy][PF6] and magnetic nanoparticles was injected into the sample solution containing the analyse of interest and a cloudy solution was forme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003