Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

نویسندگان

  • J C Rudkowski
  • P Verschelden
  • R J Kimoff
چکیده

The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous sleep study and nasoendoscopic investigation in a patient with obstructive sleep apnoea syndrome refractory to continuous positive airway pressure: a case report

INTRODUCTION The standard treatment for obstructive sleep apnoea syndrome is nasal continuous positive airway pressure. In most cases the obstruction is located at the oropharyngeal level, and nasal continuous positive airway pressure is usually effective. In cases of non-response to nasal continuous positive airway pressure other treatments like mandibular advancement devices or upper airway s...

متن کامل

An auto-continuous positive airway pressure device controlled exclusively by the forced oscillation technique.

The forced oscillation technique (FOT) has been demonstrated to be a very sensitive tool for the assessment of upper airway obstruction during nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA). The present study was designed to evaluate the therapeutic efficacy of a novel auto-CPAP device based exclusively on the FOT. Following manual CPAP titration, 18...

متن کامل

Continuous positive airway pressure titration for obstructive sleep apnoea: automatic versus manual titration.

BACKGROUND AND AIMS Manual laboratory continuous positive airway pressure (CPAP) titration for obstructive sleep apnoea (OSA) is costly, time intensive and delays access to treatment. Automatic positive airway pressure (APAP) titration has the potential to reduce cost and improve access to treatment. The aim of this study was to assess the clinical efficacy and costs of APAP titration compared ...

متن کامل

Cardiovascular aspects of obstructive sleep apnoea and their relevance to the assessment of the efficacy of nasal continuous positive airway pressure therapy.

Wright et al set out to assess the “health eVects” of obstructive sleep apnoea (OSA) and the evidence for the eYcacy of continuous positive airway pressure (CPAP) in this disorder. In their assessment they concentrated particularly on whether or not OSA causes cardiovascular disease. The review included more than 70 papers examining cardiovascular end points and less than 30 pertaining to dayti...

متن کامل

Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea.

Autotitrating continuous positive airway pressure (CPAP) devices automatically adjust the pressure according to upper airway obstructions. The aim of this study was to compare the treatment effects of different automatic CPAP devices (AutoSet, Horizon and Virtuoso) with conventional CPAP in patients with obstructive sleep apnoea independently of financial manufacturer support. Twelve male patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2001