Infant home respiratory monitoring using pulse oximetry.
نویسندگان
چکیده
Respiratory rate (RR) is a valuable early marker of illness in vulnerable infants, but current monitoring methods are unsuitable for sustained home use. We have demonstrated accurate measurement of RR from brief recordings of pulse oximeter plethysmogram (pleth) trace in full-term neonates in hospital. This study assessed the feasibility of this method in preterm infants during overnight recordings in the home. We collected simultaneous overnight SpO2, pleth and respiratory inductive plethysmography (RIP) on 24 preterm infants in the home. RR from pleth analysis was compared with RR from RIP bands; pleth quality was assessed by the presence of visible artefact. Median (range) RR from RIP and pleth were not significantly different at 42 (25-65) and 42 (25-64) breaths/min. Median (range) % of epochs rejected due to artefact was 20 (8-75) for pleth and 10 (3-53) for RIP. Our results suggest that home RR monitoring by pulse oximeter pleth signal is accurate and feasible.
منابع مشابه
Cardiocirculatory monitoring during immediate fetal-to-neonatal transition: a systematic qualitative review of the literature.
BACKGROUND The fetal-to-neonatal transition is a complex process that includes changes in cardiac and respiratory systems. OBJECTIVE The aim of this study is to review the different methods of cardiocirculatory monitoring during the immediate neonatal transition period. METHODS A systematic search of PubMed and Ovid Embase was performed using the following terms: infant, newborn, newborn in...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملNoninvasive Mechanical Ventilation. Reflections on Home Monitoring Ventilación mecánica no invasiva. Reflexiones sobre la monitorización a domicilio
Home-based noninvasive ventilation (NIV) was initiated in the early nineties in our environment as a treatment for patients with chronic respiratory failure, secondary to restrictive ventilatory disorders or neuromuscular disease. Subsequently, NIV also proved effective in patients with obesity-related hypoventilation syndromes, and to a lesser extent in some patients with chronic obstructive p...
متن کاملAccuracy and reliability of pulse oximetry in premature neonates with respiratory distress.
Continuous noninvasive monitoring of oxygenation in premature neonates with respiratory distress is essential to avoid the potential complications of hypoxemia and hyperoxia. The accuracy and reliability of pulse oximetry (using an Ohmeda Biox) was evaluated in 15 premature neonates. Pulse oximetry oxygen saturation readings closely approximated arterial oxygen saturation values analyzed by an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of disease in childhood
دوره شماره
صفحات -
تاریخ انتشار 2016