Behavior of DFIG Wind Turbines with Crowbar Protection under Short Circuit

نویسنده

  • Omar Noureldeen
چکیده

Doubly Fed Induction Generators DFIG are nowadays widely used in variable speed wind power plants. The dynamic interaction between variable speed DFIG wind turbines and the power system which is subjected to disturbances, such as short circuit faults, is an important issue. The ability of the wind power plant to stay connected to the grid during disturbances is important to avoid a cascading effect due to lack of power. This paper investigates the impact of fault ride through on the stability of DFIG wind turbine using crowbar resistance. Simulation test using MATLAB-Simulink toolbox is implemented on a 9 MW wind farm exports its power to 120 KV grid. The simulation is performed using different crowbar resistances. The variations of rotor current, rotor speed, DC-link voltage, active power and reactive power of the wind farm are investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Behavior of Wind Turbines

Synchronous generators have always been the dominant generation type in the grid. This fact affected both planning and operation of power systems. With the fast increase of wind power share in the grid in the last decade, the situation is changing. In some countries wind power represents already a consistent amount of the total generation. Wind turbines can be classified as non-synchronous gene...

متن کامل

Control and Simulation of a Crowbar Protection for DFIG Wind Turbine during Power Systems Disturbance

The use of the doubly fed induction generator (DFIG) in modern variable-speed wind turbines has increased rapidly. According to the new grid code requirements, wind turbines generators must remainconnected to the grid during grid disturbances so crowbar protections systems is being used to protect the DFIG, this paper introduces a comparison between conventional crowbar protection, series crowb...

متن کامل

Fault-Current Study of the Wind-Turbine-Driven Doubly-Fed Induction Generator with the Crowbar Protection

The crowbar protection is commonly used for wind turbines with a doubly-fed induction generator (DFIG) to enhance the low-voltage ride-through capability of the wind turbines. Thus, the fault-current characteristics of DFIG with the crowbar protection under symmetricand asymmetric-fault states are studied in this paper. Firstly, a DFIG dynamic model in the stator stationary reference frame is d...

متن کامل

Improved Control Strategy for Low Voltage Ride Through Capability of DFIG with Grid Code Requirements

This paper deals with a protection and control strategy to enhance the low voltage ride through capability of a wind turbine driven doubly fed induction generator (DFIG). As the wind power penetration continues to increase, wind turbines are required to provide Low Voltage Ride-Through (LVRT) capability. Crowbars are commonly used to protect the power converters during voltage dips and their ma...

متن کامل

Fault Ride through Capability Improvement of Wind Turbine Based DFIG Considering an Optimized Crowbar Along with STATCOM under Grid Fault Condition

Grid disturbances, especially grid faults, have very unfavorable effect on the performance of wind turbine based Doubly Fed Induction Generator (DFIG). In this study active and reactive powers control of DFIG with STATCOM has been carried out to improve Fault Ride Through (FRT) capability of a wind turbine. In order to excel improvement of the DFIG behavior under grid fault disturbances, an opt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012