Asymmetric membrane filters for the removal of leukocytes from blood.

نویسندگان

  • A Bruil
  • W G van Aken
  • T Beugeling
  • J Feijen
  • I Steneker
  • J G Huisman
  • H K Prins
چکیده

As part of a study on the mechanisms of leukocyte filtration, the influence of pore size distribution on filter efficiency was investigated. Conventional leukocyte filters are not suitable for model studies, as these filters are composed of tightly packed synthetic fibers, with a poorly defined porous structure. Therefore, open cellular polyurethane membranes with pore size distributions varying from approximately 15 to 65 microns were prepared. Filtration experiments with stacked packages of these membranes showed that leukocytes are best removed (greater than 99%) by filters with a pore size distribution of 11-19 microns. These pore sizes approach the size of leukocytes (6-12 microns). However, due to fast clogging, blood flow through these filters is rapidly reduced, which results in a low filter capacity. With an asymmetric membrane filter, in which the pore size decreases from about 65 to 15 microns in the direction of blood flow, both moderate removal of leukocytes (greater than 80%) and maintenance of flow (approximately 0.2 mL/s) are obtained. This results in efficient leukocyte removal. From cell analysis of both filtrate and filter, it is concluded that adhesion rather than sieving is the major filtration mechanism. Thus, further optimization of the filter may be achieved by surface modification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Poly(ethyleneimine) modified filters for the removal of leukocytes from blood.

Polyurethane membrane filters and filters coated with poly(ethyleneimine) were used to investigate the influence of leukocyte adhesion during filtration. Treatment of the filters with an aqueous solution of 1% (w/v) poly(ethyleneimine) (PEI) led to the introduction of amine groups at the filter surfaces, as was confirmed by X-ray photoelectron spectroscopy. The modification procedure did not si...

متن کامل

SEQUESTRATION OF LEUKOCYTES BY THE ISOLATED PERFUSED RAT LUNG

The sequestration of rat leukocytes and bone marrow cells by the lung vasculature was studied using an isolated perfused rat lung preparation. The passage of latex particles of 7.6 µm in diameter and non-hematopoietic cells through the lung blood vessels was also studied. Leukocytes and bone marrow cells were reversibly sequestered from circulation, whereas, latex particles and non-hematop...

متن کامل

Evaluation of Leukoreduction in Packed Cell Units Filtered by Home-Made Bedside Filters: Pre and Post Revision of Product Technology and Materials According to Standard Values

Introduction: Leukocytes causing a wide variety of side effects after transfusion are present in all blood products prepared by standard methods. As a consequence, the use of filter technology for leukoreduction has been widely practiced .According to AABB accreditation in 1996, leukoreduced blood components must contain less than 5×106 leukocytes per unit, but sometimes this value is higher ev...

متن کامل

مقایسۀ کارایی فیلترهای پیش ذخیره ای و پس ذخیره ای جداکننده گلبول های سفید در بیماران تالاسمی وابسته به خون

Introduction & Objective: Cellular blood products such as whole blood, packed RBC and platelet concentrate may contain a large number of donor leukocytes. These transfused cells are responsible for several transfusion reactions which include febrile reactions, platelet refractoriness due to alloimmunization and some cell associated virus transmission, especially cytomegalovirus. Advances in b...

متن کامل

Evaluation of two types of leukocyte removal filters on transfusion dependent thalassaemics.

The advent of leukocyte filters has enabled effective removal of leukocytes from certain blood products thus avoiding many adverse effects of blood transfusion. Many different materials have been incorporated into these filters to achieve >95% leukocyte removal. In this study we evaluated the efficacy of leukocyte removal of two different filters, using actual bedside transfusion settings invol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 1991