Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study.
نویسندگان
چکیده
BACKGROUND Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear. METHODS AND RESULTS Eighty-three patients underwent transfemoral (Medtronic CoreValve [MCV(TF)], n=32; Edwards Sapien [ES(TF)], n=26) and transapical (ES(TA): n=25) TAVI. Serial transcranial Doppler examinations before, during, and 3 months after TAVI were used to identify high-intensity transient signals (HITS) as a surrogate for microembolization. Procedural HITS were detected in all patients, predominantly during manipulation of the calcified aortic valve while stent valves were being positioned and implanted. The balloon-expandable ES prosthesis caused significantly more HITS (mean [95% CI]) during positioning (ES(TF), 259.9 [184.8-334.9]; ES(TA), 206.1[162.5-249.7]; MCV(TF), 78.5 [25.3-131.6]; P<0.001) and the self-expandable MCV prosthesis during implantation (MCV(TF), 397.1 [302.1-492.2]; ES(TF), 88.2 [70.2-106.3]; ES(TA), 110.7 [82.0-139.3]; P<0.001). Overall, there were no significant differences between transfemoral and transapical TAVI or between the MCV and ES prostheses. No HITS were detected at baseline or 3-month follow-up. There was 1 major procedural stroke that resulted in death and 1 minor procedural stroke with full recovery at 3-month follow-up in the MCV group. CONCLUSIONS Procedural HITS were detected by transcranial Doppler in all patients. Although no difference was observed between the transfemoral and the transapical approach with the balloon-expandable ES stent valve, transfemoral TAVI with the self-expandable MCV prosthesis resulted in the greatest number of HITS, predominantly during implantation.
منابع مشابه
Cerebral embolization during transcatheter aortic valve implantation.
The recent success of transcatheter aortic valve implantation (TAVI) has been associated with a heightened awareness of the potential risks, particularly stroke. Recent meta-analyses report 30-day stroke rates of 3% to 4%,1,2 and diffusion-weighted MRI studies have revealed new, clinically silent, cerebral lesions in 68% to 84% of patients undergoing TAVI.3–5 Although the majority of patients u...
متن کاملStroke Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study
Background—Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear....
متن کاملResponse to letters regarding article, “cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study”.
The importance of cerebral embolization as the main cause of periprocedural stroke during transcatheter aortic valve implanta-tion has recently been demonstrated. Erdoes and colleagues 1 have reported high-intensity transient signals as surrogates for micro-emboli during all phases of the procedure, predominantly during valve implantation, with no difference between transfemoral and transapical...
متن کاملThe Self-Expanding Symetis Acurate Does Not Increase Cerebral Microembolic Load When Compared to the Balloon-Expandable Edwards Sapien Prosthesis: A Transcranial Doppler Study in Patients Undergoing Transapical Aortic Valve Implantation
OBJECTIVES The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. BACKGROUND Recently, the Symetis Acurate TA revalving system has been introduce...
متن کاملTranscranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation.
OBJECTIVES Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 126 10 شماره
صفحات -
تاریخ انتشار 2012