Ultrasound-guided probe-generated artifacts stimulating ventricular tachycardia: A rare phenomenon
نویسندگان
چکیده
Electrocardiographic (ECG) artifacts may arise due to interference, faulty earthing, and current leakages in biomedical equipment which might create clinical dilemmas in the perioperative settings. Piezoelectric signals generated by ultrasonography probe are another uncommon source which might be sensed by the ECG electrodes and produce tracings similar to pathological arrhythmias triggering false alarms and avoidable therapies. Anesthesiologists should be familiar with these uncommon sources which might produce these artifacts and they should be identified swiftly.
منابع مشابه
Non-invasive cardiac pacing with image-guided focused ultrasound
Currently, no non-invasive cardiac pacing device acceptable for prolonged use in conscious patients exists. High Intensity Focused Ultrasound (HIFU) can be used to perform remote pacing using reversibility of electromechanical coupling of cardiomyocytes. Here we described an extracorporeal cardiac stimulation device and study its efficacy and safety. We conducted experiments ex vivo and in vivo...
متن کاملP-70: Ultrasound Guided Artificial Insemination:A Randomized Controlled Trial
Background: To ascertain whether using ultrasound guidance during intrauterine insemination (IUI) could increase pregnancy rates. Materials and Methods: The population under study consisted of 73 consecutive couples subjected to IUI in our Human Reproduction Unit, between September and December 2006, with a total of 231 IUI cycles performed. The patients were randomized using a computer-generat...
متن کاملRadial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre
Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...
متن کاملUltrasound-guided femoral and popliteal sciatic nerve blocks for below knee surgery in patients with severe cardiac disease
with dilated cardiomyopathy or acute myocardial infarction are at risk of anesthesia complications, and peripheral nerve blocks (PNBs) provide more stable operative hemody-namics than general anesthesia or central neuraxial blocks. We present two rare cases of patients with dilated cardiomyopathy or acute myocardial infarction and a coagulation abnormality that were administered ultrasound-guid...
متن کاملAcute myocardial infarction with isolated congenitally corrected transposition of the great arteries.
Congenital cardiac abnormalities diagnosed at the time of acute coronary syndrome are rare. A 43-year-old man presented to the emergency department complaining of recurring, severe chest pain. Subsequent emergent coronary angiography demonstrated unusual coronary anatomy: 1) one small caliber bifurcating vessel originating from the right sinus of Valsalva; 2) one very large vessel arising from ...