Navigated total knee arthroplasty (TKA) results in better restoration of neutral mechanical axis than does the conventional technique. Nevertheless, coronal malalignment has not been eliminated. It is yet unknown whether errors in implant positioning occur more on the femoral side, more on the tibial side, or equally on both sides. The hypothesis of this study was that a predominance of coronal component malalignment exists on the tibial side in navigated tibia-first TKA.Fifty-seven consecutive navigated (OrthoPilot; B. Braun Aesculap, Tuttlingen, Germany) TKAs were included in this retrospective study. Pre- and postoperative digital whole-leg standing radiographs were analyzed. Coronal alignment was measured for the whole leg pre- and postoperatively. Lateral distal femur angle and medial proximal tibia angle were analyzed on the preoperative radiographs. On the postoperative radiographs, coronal alignment of the femoral and tibial components were measured separately in reference to the tibial and femoral mechanical axis. The coronal alignment improved from 8.2° ± 3.7° preoperatively to 1.1° ± 1.2° postoperatively, with 5 (8%) outliers outside the 3° window. The femoral component was malaligned (0.6° ± 0.6°), whereas the tibial component showed a significantly higher deviation from the mechanical axis of 1.0° ± 1.1° (P=.009). The femoral component was positioned more precisely than the tibial component. The latter influences gap management in the tibia-first technique and may thereby have a relevant effect on joint stability. Accuracy of the surgical technique and differences in the mathematical algorithm for the determination of landmarks are possible reasons for the difference in precision between the femoral and tibial component positioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Navigated total knee arthroplasty in a patient with severe diaphyseal deformities.

A 65-year-old patient presented with severe osteoarthritis of the knee, 47 years after a severe polytrauma in which he had presented diaphyseal fractures of the left femur and tibia. These fractures had been treated conservatively and had healed with major deformities. He underwent total knee arthroplasty with navigation assistance. This allowed for optimal component positioning and restoration...

متن کامل

Primary resection of the posterior cruciate ligament does not produce a gap mismatch in the navigated gap technique.

Treatment of the posterior cruciate ligament (PCL) is a matter of continued controversy in total knee arthroplasty. By using so-called cruciate ligament-substituting implant designs, retention and resection of the PCL produce equivalent clinical results. However, it remains unclear whether primary resection of the PCL leads to relevant instabilities of the flexion gap. Especially when the incre...

متن کامل

More accurate component alignment in navigated total knee arthroplasty has no clinical benefit at 5-year follow-up

BACKGROUND AND PURPOSE Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study. METHODS 78 of initiall...

متن کامل

Fatigue fracture of the femur after navigated total knee replacement.

We present a case of fatigue fracture of the femur after navigated total knee arthroplasty with the Orthopilot system. A 60-year-old woman with rheumatoid arthritis and osteoporosis (T-score = -3.1) reported increasing pain of the thigh 8 weeks after the surgery. A fatigue fracture of the right femur through the pinholes was diagnosed and stabilized with an intramedullary nail, achieving union ...

متن کامل

Are systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial.

We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial embolisation in computer-assisted navigated total knee arthroplasty (n = 14) and compared this with a standard conventional surgical technique using intramedullary alignment guides (n = 10). All patients were selected randomly without the knowledge of the patient, anaesthetists (bef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 10 Suppl  شماره 

صفحات  -

تاریخ انتشار 2012