A simplified two-component model of blood pressure fluctuation.

نویسندگان

  • Robert J Brychta
  • Richard Shiavi
  • David Robertson
  • Italo Biaggioni
  • André Diedrich
چکیده

We propose a simple moving-average (MA) model that uses the low-frequency (LF) component of the peroneal muscle sympathetic nerve spike rate (LF(spike rate)) and the high-frequency (HF) component of respiration (HF(Resp)) to describe the LF neurovascular fluctuations and the HF mechanical oscillations in systolic blood pressure (SBP), respectively. This method was validated by data from eight healthy subjects (23-47 yr old, 6 male, 2 female) during a graded tilt (15 degrees increments every 5 min to a 60 degrees angle). The LF component of SBP (LF(SBP)) had a strong baroreflex-mediated feedback correlation with LF(spike rate) (r = -0.69 +/- 0.05) and also a strong feedforward relation to LF(spike rate) [r = 0.58 +/- 0.03 with LF(SBP) delay (tau) = 5.625 +/- 0.15 s]. The HF components of spike rate (HF(spike rate)) and SBP (HF(SBP)) were not significantly correlated. Conversely, HF(Resp) and HF(SBP) were highly correlated (r = -0.79 +/- 0.04), whereas LF(Resp) and LF(SBP) were significantly less correlated (r = 0.45 +/- 0.08). The mean correlation coefficients between the measured and model-predicted LF(SBP) (r = 0.74 +/- 0.03) in the supine position did not change significantly during tilt. The mean correlation between the measured and model-predicted HF(SBP) was 0.89 +/- 0.02 in the supine position. R(2) values for the regression analysis of the model-predicted and measured LF and HF powers indicate that 78 and 91% of the variability in power can be explained by the linear relation of LF(spike rate) to LF(SBP) and HF(Resp) to HF(SBP). We report a simple two-component model using neural sympathetic and mechanical respiratory inputs that can explain the majority of blood pressure fluctuation at rest and during orthostatic stress in healthy subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology A simplified two-component model of blood pressure fluctuation

Brychta RJ, Shiavi R, Robertson D, Biaggioni I, Diedrich A. A simplified two-component model of blood pressure fluctuation. Am J Physiol Heart Circ Physiol 292: H1193–H1203, 2007. First published September 29, 2006; doi:10.1152/ajpheart.00645.2006.—We propose a simple moving-average (MA) model that uses the low-frequency (LF) component of the peroneal muscle sympathetic nerve spike rate (LFspik...

متن کامل

A Novel Equivalent Circuit for Induction Motors under Voltage Fluctuation Conditions

Voltage fluctuation is one of the important types of power quality aspects originated from heavy fluctuating loads. This phenomenon can influence the behavior of induction motors, produce excessive vibration and increase the ohmic losses. In this paper a simplified model to evaluate the electrical characteristics of three phase induction motors under voltage fluctuation conditions will be prese...

متن کامل

The Effect of Continuous Care Model on Diabetic Patients’ Blood Pressure

Introduction: Hypertension can accelerate other complications of diabetes mellitus, particularly cardiovas-cular disease and nephropathy. This study was carried out in order to determine the effect of applying Continuous Care Model on diabetic patients’ blood pressure. Methods: This clinical trial was performed as time series on 74 patients with diabetes mellitus type II, in Orumieh in the yea...

متن کامل

Flow Pattern and Oil Holdup Prediction in Vertical Oil–Water Two–Phase Flow Using Pressure Fluctuation Signal

In this work, the feasibility of flow pattern and oil hold up the prediction for vertical upward oil–water two–phase flow using pressure fluctuation signals was experimentally investigated. Water and diesel fuel were selected as immiscible liquids. Oil hold up was measured by Quick Closing Valve (QCV) technique, and five flow patterns were identified using high-speed photo...

متن کامل

Monte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models

Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 292 2  شماره 

صفحات  -

تاریخ انتشار 2007