Experimental determination of the Task Group-43 dosimetric parameters of the new I25.S17plus (125)I brachytherapy source.

نویسندگان

  • Argyris Moutsatsos
  • Evaggelos Pantelis
  • Panagiotis Papagiannis
  • Dimos Baltas
چکیده

PURPOSE To present experimental dosimetry results for the new IsoSeed I25.S17plus (125)I brachytherapy source, in fulfillment of the American Association of Physicists in Medicine recommendation for, at least one, experimental dosimetry characterization of new low-energy seeds before their clinical implementation. METHODS AND MATERIALS A batch of 100 LiF thermoluminescent dosimeter (TLD)-100 microcubes was used for the experimental determination of the dose-rate constant, radial dose, and anisotropy functions, in irradiations performed using two Solid Water phantoms. Monte Carlo (MC) simulations were used to determine appropriate correction factors that account for the use of Solid Water as a phantom material instead of liquid water and for the different energy response of the TLD dosimeters in the experimental (125)I photon energies relative to the 6 MV x-ray photon beam used for the TLD calibration. Measurements were performed for four I25.S17plus seeds; one with direct traceability of air-kerma strength calibration to National Institute of Standards and Technology and three with secondary National Institute of Standards and Technology traceability. RESULTS A mean dose-rate constant, Λ, of 0.956 ± 0.043 cGy h(-1) U(-1) was experimentally determined for the I25.S17plus source, which agrees within uncertainties with the MC result of 0.925 ± 0.013 cGy h(-1) U(-1) calculated independently for the same seed model in a previous study. Agreement was also observed between the measured and the MC-calculated radial dose and anisotropy function values. CONCLUSIONS Experimental dosimetry results for the I25.S17plus (125)I source verify corresponding independent MC results in the form of Task Group-43 dosimetry parameters. The latter are found in agreement within uncertainties with sources of similar design incorporating a silver marker, such as the Oncura OncoSeed Model 6711.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New 125I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design

PURPOSE To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of similar design. MATERIAL AND METHODS Monte Carlo simulations were performed using the MCNP5 v.1.6 ...

متن کامل

Dosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code

Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...

متن کامل

Determination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...

متن کامل

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

Determination of Dosimetric characteristics of a New 192Ir-PDR Brachytherapy Source According to AAPM TG- 43 Protocol using Monte Carlo simulation technique

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 13 6  شماره 

صفحات  -

تاریخ انتشار 2014