Pattern Classification of Partial Discharge in Lv Winding of 1- Transformer Using Pca

نویسندگان

  • Ganesh Rao
  • Shailja Shukla
چکیده

Partial discharge is the commencement of failure of insulation of electrical devices used at high voltage. If such discharge is not detected then fault may increase at the working duration. Basically partial discharge is the cause of failure of insulation in electrical equipment. The insulation of electrical equipment deteriorates due to thermal, mechanical, electrical and environmental stresses. Continuous on-line monitoring of partial discharge (PD) activities involves recording large amounts of data and it is hallenging task to extract useful information from them. This paper proposes a partial discharge analysis and its pattern classification in LV winding of single phase Transformer using straight or electrical technique for analysis and principle component analysis algorithm for recognition of partial discharge pattern. Getting different patterns by changing fault location, we can classify these patterns according to their position in the LV winding. To measure the partial discharge we have different technique like direct or electrical method, acoustic measurement, balance. In this paper electrical method is used in which PD Analyzer DDX-9101 is used in which we get the 2-D pattern in sinusoidal waveform at different voltage level by changing location of fault in LV winding. When we vary voltage level with changing location of fault in LV winding we get variation in peaks level and also peaks location i.e. in +ve and –ve half cycle. By analysis of these peaks level and peaks location at different fault location we can analysie these pattern and also recognize or classify these partial discharge pattern with the help of principle component analysis (PCA) algorithm. It has been concluded that the discharge magnitude (PD level) will be very low if fautl is at near supply end, as we go onwards to the supply end discharge magnitude will increase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

متن کامل

Investigation of Partial Discharge Propagation and Location in Multiple-α and Single- Α Transformer Windings Using Optimized Wavelet Analysis

Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...

متن کامل

مدلسازی سیم پیچ ترانسفورماتورهای قدرت با استفاده از مدل خط انتقال چند سیمه بمنظور مکانیابی تخلیه جزئی

In this paper Multi conductor transmission line model (MTLM) was used for partial discharge (PD) localization in power transformers’ windings. The parameters of the model were computed considering practical issues of power transformer design. To decrease computational complexity of the model, two methods for calculation of model parameters were studied and the most suitable method was cho...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Partial Discharge Location within a Transformer Winding Using Principal Component Analysis

Partial discharge (PD) may occur in a transformer winding due to ageing processes, operational over stressing or defects introduced during manufacture. The presence of PD does not necessarily indicate imminent failure of the transformer but it will lead to serious degradation and ageing mechanisms which can be considered as a precursor of transformer failure. A necessary step is required in ord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010