Relative intelligibility of the revised CID W-1s as presented via MLV and auditec recordings.
نویسندگان
چکیده
The relative intelligibility of the revised CID W-1 spondaic word list, as developed and recommended for clinical use by ASHA, was evaluated in two experiments. In Experiment 1, the revised W-1s were presented via monitored live voice to 25 subjects with normal hearing. Mean minimum recognition levels for each of the 36 spondees varied between 16.8 and 25.2 dB SPL, a range of 8.4 dB. In Experiment 2, the Auditec recordings of the revised W-1s were presented to a different group of 20 subjects with normal hearing. Mean minimum recognition values for the individual spondees varied between 18.1 and 30.6 dB SPL, a range of 12.5 dB. Thus, the homogeneity of audibility for the revised W-1s is no better than has been noted in the past for the original W-1s and, in the case of the Auditec recording, is considerably worse. A reduced list of spondees with improved homogeneity of audibility is recommended for clinical use.
منابع مشابه
Speech intelligibility of the callsign acquisition test in a quiet environment.
This paper reports on preliminary experiments aimed at standardizing speech intelligibility of military Callsign Acquisition Test (CAT) using average power levels of callsign items measured by the Root Mean Square (RMS) and maximum power levels of callsign items (Peak). The results obtained indicate that at a minimum sound pressure level (SPL) of 10.57 dBHL, the CAT tests were more difficult th...
متن کاملEquivalency of Sentence Intelligibility Lists for Audiological Assessment of Naval Personnel and Navy Voice Communication Systems
The purpose of this study was to investigate the equivalency of several sentence intelligibility lists for use in clinical hearing tests of Navy personnel and research facilities requiring figure-of-merit indices of voice communication systems. Ten Central Institute for the Deaf (CID) Sentence Intelligibility Lists and revisions of those ten lists (R-CID) were presented to two groups of 30 list...
متن کاملNKI-CCRT Corpus - Speech Intelligibility Before and After Advanced Head and Neck Cancer Treated with Concomitant Chemoradiotherapy
Evaluations of speech intelligibility based on a read passage are often used in the clinical situation to assess the impact of the disease and/or treatment on spoken communication. Although scale-based measures are often used in the clinical setting, these measures are susceptible to listener response bias. Automatic evaluation tools are being developed in response to some of the drawbacks of p...
متن کاملThe consistency of sentence intelligibility across three types of signal distortion.
PURPOSE To examine the extent to which sentences retain their levels of spoken intelligibility relative to other sentences in a set (the sentence effect) across different types of signal distortion. METHOD The Central Institute for the Deaf (CID) sentences were rendered difficult to understand through the addition of broadband noise. These intelligibility data were compared with those from pr...
متن کاملPREPARATION AND SINTERING OF W-20%Wt Cu COMPOSITE POWDERS PRODUCED BY CO-PRECIPITATION METHOD
Abstract: materials can be fabricated by sintering of W-Cu composite powders. In this research W-20%wt Cu composite powderswas synthesized via a co-precipitation method. Precipitate obtained from a mixture of copper nitrate and ammoniumparatungstate (APT) in distilled water contained W-Cu compounds. This precipitate was washed, dried and calcinedat 550 of dried precipitate powder was determined...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 6 2 شماره
صفحات -
تاریخ انتشار 1995