A 2-D model for the corrosion of spent nuclear fuel inside a failed nuclear waste container has been modified to determine the influence of various redox processes occurring within fractures in the fuel. The corrosion process is driven by reaction of the fuel with the dominant α radiolysis product, H2O2. A number of reactions are shown to moderate or suppress the corrosion rate, including H2O2 decomposition and a number of reactions involving dissolved H2 produced either by α radiolysis or by the corrosion of the steel container vessel. Both sources of H2 lead to the suppression of fuel corrosion, with their relative importance being determined by the radiation dose rate, the steel corrosion rate, and the dimensions of the fractures in the fuel. The combination of H2 from these two sources can effectively prevent corrosion when only micromolar quantities of H2 are present.
منابع مشابه
A model for the influence of steel corrosion products on nuclear fuel corrosion under permanent disposal conditions
A model was developed to determine the influence of steel corrosion products on a-radiolytic corrosion of spent nuclear fuel inside a failed waste container. The model takes into account the a-radiolysis of water, the reaction of radiolytic H2O2 with UO2 both directly and via galvanic coupling with noble metal particles, the reaction with H2 via galvanic coupling, and the Fenton reaction. The d...
متن کاملModeling the Radiolytic Corrosion of Fractured Nuclear Fuel under Permanent Disposal Conditions
A two-dimensional model has been developed to simulate the corrosion of nuclear fuel pellets under permanent waste disposal conditions in a steel vessel with a corrosion-resistant copper shell. The primary emphasis was on the corrosion behavior within cracks with various dimensions. It was shown that a simplified α-radiolysis model which only accounts for the radiolytic production of H2O2 and H...
متن کاملInteractions between Carbon Steel and Uo2 Corrosion Fronts inside a Failed Nuclear Waste Container
The corrosion of carbon steel in the chloride-dominated groundwaters anticipated inside a failed spent fuel waste container has been studied in the presence of small concentrations of added hydrogen peroxide. Solutions with peroxide concentrations in the micro-molar range were found to accelerate steel corrosion slightly leading to the formation of Fe-containing corrosion product deposits but n...
متن کاملAn improved model for the corrosion of used nuclear fuel inside a failed waste container under permanent disposal conditions
An improved model for nuclear fuel corrosion inside a failed waste container has been developed. The model considers the influence of the a-radiolysis products using a full radiolytic reaction set, and demonstrates that H2O2 is the dominant oxidant. Corrosion of the fuel is modelled considering both the direct oxidation of UO2 by H2O2 and the galvanically-coupled oxidation by H2O2 reduction on ...
متن کاملSafety Analysis of Spent Fuel Transportation Cask of Bushehr Nuclear Power Plant through the Passing of Fire Tunnel with ANSYS®10.0
The spent fuel assemblies (FAs) of Bushehr Nuclear Power Plant are planed to be transported by TK-13 casks. Each spent fuel transportation cask holds 12 spent FAs and has a thick steel container to provide shielding. The calculations have been performed for FAs with burn ups of 60 MWd/kg and a 3-years cooling period. The ANSYS®10.0 general finite element analysis package was se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental science & technology
دوره 50 22 شماره
صفحات -
تاریخ انتشار 2016