Simulation and evaluation of a high resolution VIP PEM system with a dedicated LM-OSEM algorithm.

نویسندگان

  • D Uzun
  • G De Lorenzo
  • M Kolstein
  • M Chmeissani
چکیده

Over the last two decades there have been a growing number of designs for positron emission tomography (PET) cameras optimized to image the breast. These devices, commonly known as positron emission mammography (PEM) cameras allow much more spatial resolution by putting the photon detectors directly on the breast. PEM cameras have a compact geometry with a restricted field of view (FOV) thus exhibiting higher performance and lower cost than large whole body PET scanners. Typical PEM designs are based on scintillators such as bismuth germanate (BGO), lutetium oxorthosilicate (LSO) or lutetium yttrium orthosicilate (LYSO), and characterized by large parallax error due to deficiency of the depth of interaction (DOI) information from crystals. In the case of parallel geometry PEM, large parallax error results in poor image resolution along the vertical axis. In the framework of the Voxel Imaging PET (VIP) pathfinder project, we propose a high resolution PEM scanner based on pixelated solid-state CdTe detectors. The pixel PEM device with a millimeter-size pixel pitch provides an excellent spatial resolution in all directions 8 times better than standard commercial devices with a point spread function (PSF) of 1 mm full width at half maximum (FWHM) and excellent energy resolution of down to 1.6% FWHM at 511 keV photons at room temperature. The system is capable to detect down to 1 mm diameter hot spheres in warm background.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of channels

The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). For Compton camera, especially with a large numbe...

متن کامل

Optimization, evaluation, and comparison of standard algorithms for image reconstruction with the VIP-PET

A novel positron emission tomography (PET) scanner design based on a room-temperature pixelated CdTe solid-state detector is being developed within the framework of the Voxel Imaging PET (VIP) Pathfinder project [1]. The simulation results show a great potential of the VIP to produce high-resolution images even in extremely challenging conditions such as the screening of a human head [2]. With ...

متن کامل

Evaluation of 3D Reconstruction Algorithms for a Small Animal PET Camera

The use of paired, opposing position-sensitive phototube scintillation cameras (SCs) operating in coincidence for small animal imaging with positron emitters is currently under study. Because of the low sensitivity of the system even in 3D mode and the need to produce images with high resolution, it was postulated that a 3D expectation maximization (EM) reconstruction algorithm might be well su...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of instrumentation : an IOP and SISSA journal

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2014