External respiratory motion analysis and statistics for patients and volunteers

نویسندگان

  • Sarah Quirk
  • Nathan Becker
  • WL Smith
چکیده

We analyzed a large patient and volunteer study of external respiratory motion in order to develop a population database of respiratory information. We analyzed 120 lung, liver, and abdominal patients and 25 volunteers without lung disease to determine the extent of motion using the Varian Real-Time Position Management system. The volunteer respiratory motion was measured for both abdominal and thoracic placement of the RPM box. Evaluation of a subset of 55 patients demonstrates inter- and intrafraction variation over treatment. We also calculated baseline drift and duty cycle for patients and volunteers. The mean peak-to-peak amplitude (SD) for the patients was 1.0 (0.5) cm, and for the volunteers it was abdomen 0.8 (0.3) cm and thoracic 0.2 (0.2) cm. The mean period (SD) was 3.6 (1.0) s, 4.2 (1.1)s, and 4.1 (0.8) s, and the mean end exhale position (SD) was 60% (6), 58% (7), and 56% (7) for patient, volunteer abdomen, and volunteer thoracic, respectively. Baseline drift was greater than 0.5 cm for 40% of patients. We found statistically significant differences between the patient and volunteer groups. Peak-to-peak amplitude was significantly larger for patients than the volunteer abdominal measurement and the volunteer abdominal measurement is significantly larger than the volunteer thoracic measurement. The patient group also exhibited significantly larger baseline drift than the volunteer group. We also found that peak-to-peak amplitude was the most variable parameter for both intra- and interfraction motion. This database compilation can be used as a resource for expected motion when using external surrogates in radiotherapy applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Boston Brace on Muscle Length of Patients with Idiopathic Scoliosis

Purpose: This study aimed to assess the effect of Boston brace on trunk muscles length as well as lower limbs and trunk range of motion in patients with idiopathic scoliosis. Methods: Five patients with idiopathic scoliosis with C shape curve and mean (SD) age, height, and weight of respectively 12.61(1.16) years, 1.53(0.08) m, and 35.6(6.1) kg participated in this study. Spatiotemporal para...

متن کامل

Marker-less respiratory motion modeling using the Microsoft Kinect for Windows

Patient respiratory motion is a major problem during external beam radiotherapy of the thoracic and abdominal regions due to the associated organ and target motion. In addition, such motion introduces uncertainty in both radiotherapy planning and delivery and may potentially vary between the planning and delivery sessions. The aim of this work is to examine subject-specific external respiratory...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study

Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...

متن کامل

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013