Realization and application of a detector-based tristimulus color scale at the National Institute of Standards and Technology, USA
نویسندگان
چکیده
The recently introduced detector-based calibration method for tristimulus colorimeters has been realized. The NIST reference colorimeter has been calibrated for spectral irradiance responsivity with an uncertainty of 0.15 % (coverage factor k=2) resulting in a chromaticity uncertainty of 0.0004 (k=2) in the x and y chromaticity coordinates when a CIE Illuminant A source is measured. The color scale is realized and maintained by reference colorimeters rather than reference lamps. The color measurement uncertainty increases when sources other than Illuminant A are measured due to spectral mismatch errors of the channels. Variable reference source models have been developed so that the reference source for the colorimeter can be automatically matched to the measured test source of certain types. A model using Planckian radiation with a variable temperature has been tested and proved to be effective in eliminating the mismatch errors for incandescent lamps. Another model based on primary colors of a display has also been tested and shown to be effective.
منابع مشابه
Comparison of Calibration Methods for Tristimulus Colorimeters
Uncertainties in source color measurements with a tristimulus colorimeter are estimated for calibration factors determined, based on a known source spectral distribution or on accurate measurements of the spectral responsivities of the colorimeter channels. Application is to the National Institute of Standards and Technology (NIST) colorimeter and an International Commission on Illumination (CI...
متن کاملSpectral Response Based Calibration Method of Tristimulus Colorimeters
A new method is described to calibrate tristimulus colorimeters for high accuracy color measurements. Instead of traditional lamp standards, modern, high accuracy detector standards are suggested for calibration. After high accuracy absolute spectral response determination of the tristimulus receivers, color (spectral) correction and peak (amplitude) normalization can minimize uncertainties cau...
متن کاملRealization of the National Institute of Standards and Technology detector-based spectral irradiance scale.
A detector-based spectral irradiance scale has been realized at the National Institute of Standards and Technology (NIST). Unlike the previous NIST spectral irradiance scales, the new scale is generated with filter radiometers calibrated for absolute spectral power responsivity traceable to the NIST high-accuracy cryogenic radiometer instead of with the gold freezing-point blackbody. The calibr...
متن کاملEffects of Gamma Irradiation on Residual Nitrite, Lipid Oxidation, Total Volatile Nitrogen and Color in Meat Products with Various Meat Contents
Background and Objectives: Gamma irradiation has been shown as an effective technology to decrease or eliminate microbial contamination in raw and cooked meat products. However, irradiation-induced physicochemical changes are important to accept the technology by meat industries and consumers. The objective of this study was to assess effects of gamma irradiation (0, 2, 4, 6 and 8 kGy) on nitri...
متن کاملSynthesis and Application of Two Organic Dyes Based on Indoline in Dye-Sensitized Solar Cells
In this paper we sensitized two new organic days dye 1 and dye 2 based on thioindigo with phenothiazine as the electron donor group. We used acrylic acid and cyanoacrylic acid as the electron acceptor anchoring group in dye 1 and dye 2 respectively. The proposed dyes were sensitized from phenothiazine as the starting material by standard reactions and characterized by different techniques such ...
متن کامل