Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
نویسندگان
چکیده
OBJECTIVES This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals. METHOD In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively. RESULTS The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects. CONCLUSIONS Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain.
منابع مشابه
The Intrarater Reliability of Rehabilitation Ultrasonography and Linear and Cross Sectional Measurements of the Lumbar Multifidus Muscles in Normal Subjects
Objective: Using rehabilitation ultrasonography imaging (RUSI) is widely growing in the physiotherapy clinics of developed countries. Due to this new application, it is necessary to consider the repeatability of this new technique by novice physiotherapists and applied methods to measure the muscle size. This study has been designed to investigate the intrarater reliability and also the relatio...
متن کاملمقایسه ضخامت عضلات اکستانسور گردنی در زنان مبتلا به گردندرد مزمن غیراختصاصی و افراد سالم با استفاده از اولتراسونوگرافی
Objective: Neck pain is one of the most common musculoskeletal disorders. Structural and functional alteration of cervical muscles is a commonly-reported complication of chronic neck pain (CNP). Measurement of muscle thickness is an acceptable way to evaluate muscle morphological structure. Therefore, this study aimed to measure cervical extensor muscles thickness in individuals with chronic no...
متن کاملبررسی ابعاد عضله سمی اسپاینالیس کپیتیس و قدرت ایزومتریک عضلات اکستانسور گردن در وضعیت های مختلف در زنان سالم
Background and purpose: Ultrasonography is a reliable and valid method to assess the strength of neck extensors and measuring the neck muscles dimensions. Cervical muscles strength and dimensions may change in different positions. The aim of this study was to compare the strength of cervical extensor muscles and dimensions of semi-spinalis capitis muscle (SECM) in three different neck positions...
متن کاملIntra-rater reliability of sonographic measurement of the upper trapezius, supraspinatus and deltoid muscles in women with frozen shoulder and healthy women
Background: Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to invest...
متن کاملThe Functional Correction of Forward Shoulder Posture with Kinesiotape Improves Chest Mobility and Inspiratory Muscle Strength: A Randomized Controlled Trial
Background. Kinesiotape (K-tape) application can attenuate postural malalignment. However, the effects of K-tape on the changes in the respiratory system in postural problems remain unclear. Objectives. This study investigated the effects of 6-week functional correction with the K-tape on the forward shoulder posture (FSP) and respiratory function. Methods. A randomized clinical trial was per...
متن کامل