Trilateral Intercomparison of Photometric Units Maintained at NIST (USA), NPL (UK), and PTB (Germany)
نویسندگان
چکیده
Physikalisch-Technische Bundesanstalt, Abteilung Optik, Photometrie, Postfach 33 45, 38023 Braunschweig, Germany A trilateral intercomparison of photometric units between NIST (USA), NPL (UK), and PTB (Germany) has been conducted to update the knowledge of the relationship between the photometric units disseminated in the three countries. The luminous intensity unit (cd), the luminous responsivity scale (A/lx), and the luminous flux unit (lm) maintained at each laboratory were compared by circulating transfer standard lamps and photometers. The results showed that the relative luminous intensity values, with respect to the average, measured by NIST, NPL, and PTB were 1.0014, 1.0021, and 0.9966; the relative inverse values of the luminous responsivity (corresponding to illuminance) were 1.0023, 1.0011, and 0.9965; the relative luminous flux values were 0.9994, 1.0034, and 0.9972, respectively. The results agreed within the stated uncertainties of the units maintained at the three laboratories.
منابع مشابه
1993 Intercomparison of Photometric Units Maintained at NIST (USA) and PTB (Germany)
A bilateral intercomparison of photometric units between NIST, USA and PTB, Germany has been conducted to update the knowledge of the relationship between the photometric units disseminated in each country. The luminous intensity unit (cd) and the luminous flux unit (lm) maintained at both laboratories are compared by circulating transfer standard lamps. Also, the photometric responsivity sv is...
متن کاملSummary of the Intercomparison of the Force Standard Machines of the National Institute of Standards and Technology, USA, and the Physikalisch-Technische Bundesanstalt, Germany
A comparison of force measurements performed at the National Institute of Standards and Technology, USA, and at the Physikalisch-Technische Bundesanstalt, Germany is reported. The focus of the study was the intercomparison of the forces realized by the two Institutes rather than the measurement process. The transfer standards used in the comparison consisted of force transducers and associated ...
متن کاملPreparative Steps Towards the New Definition of the Kelvin in Terms of the Boltzmann Constant
The International Committee for Weights and Measures (CIPM) approved, in its Recommendation 1 of 2005, preparative steps towards new definitions of the kilogram, the ampere, the kelvin, and the mole in terms of fundamental constants. Within the Consultative Committee for Thermometry (CCT), a task group (TG-SI) H. Ugur is the President, Consultative Committee for Thermometry (CCT). J. Fischer (B...
متن کاملImproved Photometric Standards and Calibration Procedures at NIST
NIST has recently established a detector-based luminous intensity unit (candela, cd), which is derived from the NIST absolute cryogenic radiometer. Subsequently, the luminous flux unit (lumen, lm) and the luminance unit (cd/m2) have been established based on the detector-based candela, and now all the NIST photometric units are tied to the cryogenic radiometer. The illuminance unit is realized ...
متن کاملThe 1996 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers
Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, th...
متن کامل