Post-Launch Analysis of Swift’s Gamma-Ray Burst Detection Sensitivity
نویسنده
چکیده
The dependence of Swift’s detection sensitivity on a burst’s temporal and spectral properties shapes the detected burst population. Using simplified models of the detector hardware and the burst trigger system I find that Swift is more sensitive to long, soft bursts than CGRO’s BATSE, a reference detector because of the large burst database it accumulated. Thus Swift has increased sensitivity in the parameter space region into which time dilation and spectral redshifting shift high redshift bursts. Subject headings: gamma-rays: bursts — instrumentation: detectors
منابع مشابه
The Synergy of Gamma-ray Burst Detectors in the Glast Era
Simultaneous observations by the large number of gamma-ray burst detectors operating in the GLAST era will provide the spectra, lightcurves and locations necessary for studying burst physics and testing the putative relations between intrinsic burst properties. The detectors’ energy band and the accumulation timescale of their trigger system affect their sensitivity to hard vs. soft and long vs...
متن کاملCorrelative Spectral Analysis of Gamma-Ray Bursts using Swift-BAT and GLAST-GBM
We discuss the preliminary results of spectral analysis simulations involving anticipated correlated multiwavelength observations of gamma-ray bursts (GRBs) using Swift’s Burst Alert Telescope (BAT) and the Gamma-Ray Large Area Space Telescope’s (GLAST) Burst Monitor (GLAST-GBM), resulting in joint spectral fits, including characteristic photon energy (
متن کاملThe Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs
We report on recent inter-calibration studies featuring Swift’s Burst Alert Telescope (BAT) and Fermi’s Gammaray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift’s intrinsic multi-wavelength instrumentation and dynamical response complement Fermi’s superior energy range. The addition of BAT’s spectral response w...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملThe GLAST Burst Monitor
The next large NASA mission in the field of gamma-ray astronomy, GLAST, is scheduled for launch in 2007. Aside from the main instrument LAT (Large-Area Telescope), a gamma-ray telescope for the energy range between 20 MeV and > 100 GeV, a secondary instrument, the GLAST burst monitor (GBM), is foreseen. With this monitor one of the key scientific objectives of the mission, the determination of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006